Test Instrument for Measuring the Electrical Safety of Medical Devices
Preconfigured test sequences for quickly testing simple operating equipment. One test sequence executed with individual measurements. Suitable for use by instructed persons. Comprehensive data management and storage concept for test results and individual measurements (up to 50,000 data records*) - assignment of measurements/tests to devices and clients. Fast access to measurement and test functions with double rotary switch, direct selection keys and softkeys. High-resolution, brilliant 4.3" TFT color display. Unique multiple measurement allows for the convenient recording of several measuring points. Automatic DUT connection and protection class detection. Compact, impact-resistant housing with integrated rubber protector. Comprehensive, legally secure preparation of test reports. Interfaces for data entry (2x USB A) and data exchange (1x USB B). Extensive setting options for international use (language, keyboard, character set, date, time). Testing of different PRCD types, e.g. PRCD-S/PRCD-K (also with protective conductor resistance measurement for variants with connected PE) with the integrated test sequence “VDE 0701-0702-PRCD”
Options:
- B05: USA Plugs
- C01: English User Interface
- E01: Data entry via touchscreen
- G01: 200 mA und 10 A 1 (not in combination with G02)
- I01: DVM function (digital voltmeter) with 2 additional measurement inputs, COM-V
- KB00
- KC01
- KE01
- M01: Bluetooth
- V01
Database Expansions for SECUTEST DB+ (Z853R)
- Remote Control via PC software (IZYTRONIQ) possible.
- Additional Database elements for property, building, floor, and room for a better structuring of large data volumes and additional fields for department and cost center
- Multiprint - Print-Out of Several / All Test Reports (to a connected Z721S thermal printer) which are available for a device under test by pressing just one key
- Create user-defined report templates and manage them in the SECUTEST, including company logo
- Data Export of all data (master data and measured values) as a file to a USB flash drive
- Data Import of all DUT master data (except measured values) from IZYTRONIQ or a USB flash drive into the SECUTEST
- Create User-Defined Test Sequences in IZYTRONIQ and upload them to the SECUTEST
- Database field test interval
Database Expansions for SECUTEST DB COMFORT (Z853S)
- New database object Medicine - Device with extended entry options
- The search function via the “Search all” softkey also allows for searching in the new field “UDI” (Unique Device Identification) of medical devices.
- User-Defined Test Sequences - the number of user-defined sequences has now been increased to 24
- Shifting of test objects - the “shifting” of a (medical) device within the tree can be initiated by pressing and holding onto the tree symbol in the main display.
- Touchedit - the “editing” of a (medical) device can be opened by pressing and holding onto the detailed view in the main display.
- Autostore - the Autostore function can be activated in the setup so that test results of the automatic test can be stored immediately under the selected test object.
- PushPrint - A PC connected with the test instrument can put the SECUTEST in another operating mode in which the data are sent directly to the connected PC instead of saving them.
- QuickEdit - When entering a new DUT, the QuickEdit option can be activated, thus enabling the user to enter all other fields in one go after entry of the ID numbers.