| PROFITEST |
INTRO |
MBASE+ |
MPRO |
MTECH+ |
MXTRA |
| |
|
|
|
|
|
| RCD measurements |
|
|
|
|
|
| UB measurement without tripping the RCD |
x |
x |
x |
x |
x |
| Tripping time measurement |
x |
x |
x |
x |
x |
| Tripping current measurement |
x |
x |
x |
x |
x |
| Selective, SRCDs, PRCDs, type G/R |
x |
x |
x |
x |
x |
| AC/DC sensitive RCDs, types B and B+ |
x |
- |
- |
x |
x |
| Testing of insulation monitoring devices (IMDs) |
- |
- |
- |
- |
x |
| Testing of residual current monitoring devices (RCMs) |
- |
- |
- |
- |
x |
| Testing for N-PE reversal |
x |
x |
x |
x |
x |
| Loop impedance ZL-PE / ZL-N |
|
|
|
|
|
| Fuse table for systems without RCDs |
x |
x |
x |
x |
x |
| Without tripping the RCD, fuse table |
x |
- |
- |
x |
x |
| With 15 mA test current without tripping the RCD |
x |
x |
x |
x |
x |
| Earth resistance |
|
|
|
|
|
Earth resistance RE (mains operation)
I-U measuring method (2/3-wire measuring method
via measuring adapter: 2-wire/2-wire + probe), (1 = without probe) |
x(1) |
x |
x |
x |
x |
Earth resistance RE (battery operation)
3 or 4-wire measuring method via PRO-RE adapter |
- |
- |
x |
- |
x |
| Soil resistivity ρE (battery operation) (4-wire measuring method via PRO-RE adapter) |
- |
- |
x |
- |
x |
| Selective earth resistance RE (mains operation) with 2-pole adapter, probe, earth electrode and current clamp sensor (3-wire measuring method) |
- |
x |
x |
x |
x |
| Selective earth resistance RE (battery operation) with probe, earth electrode and current clamp sensor (4-wire measuring method via PRO-RE adapter and current clamp sensor) |
- |
- |
x |
- |
x |
| Earth loop resistance ρELOOP (battery operation) with 2 clamps (current clamp sensor direct and current clamp transformer via PRO-RE/2 adapter) |
- |
- |
x |
- |
x |
Equipotential bonding measurement RLO
with automatic polarity reversal |
x |
x |
x |
x |
x |
Insulation resistance RINS
with variable or rising (ramp) test voltage |
x |
x |
x |
x |
x |
| Variable or rising test voltage |
x |
x |
x |
x |
x |
Voltage measurement
UL-N / UL-PE / UN-PE / f |
x |
x |
x |
x |
x |
| Special measurements |
|
|
|
|
|
Leakage current (clamp measurement) IL, IAMP
phase sequence
earth leakage resistance RE(INS)
voltage drop
standing surface insulation ZST
meter start-up |
-
x
x
x
-
- |
x
x
x
x
x
x |
x
x
x
x
x
x |
x
x
x
x
x
x |
x
x
x
x
x
x |
| Leakage current with PRO-AB adapter |
- |
- |
- |
- |
x |
| Residual voltage test |
- |
- |
- |
- |
x |
| Intelligent ramp |
- |
- |
- |
- |
x |
| Features |
|
|
|
|
|
| Selectable user interface language |
x |
x |
x |
x |
x |
| Memory (database for up to 50,000 objects) |
x |
x |
x |
x |
x |
| Test sequence auto-function (programmable) |
- |
x |
x |
x |
x |
| RS 232 port for RFID/barcode reader |
x |
x |
x |
x |
x |
| USB port for data transmission |
x |
x |
x |
x |
x |
| Interface for Bluetooth® |
- |
- |
- |
x |
x |
| ETC user software for PC |
x |
x |
x |
x |
x |
| Measuring category: CAT III 600 V / CAT IV 300 V |
x |
x |
x |
x |
x |
DAkkS calibration
(2 = factory calibration certificate) |
(2) |
x |
x |
x |
x |
| Article Number |
M520T |
M520S |
M520N |
M520R |
M520P |
| PROFITEST |
INTRO |
MBASE+ |
MPRO |
MTECH+ |
MXTRA |