General |
Intrinsic error | Refers to the reference conditions and is guaranteed for two years |
Warranty | 2 years |
Recalibration interval | 2 years recommended |
Quality system | developed, designed, and manufactured according to DIN ISO 9001 |
Reference conditions | 23°C ±2K, Um=230 V ±10%, 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz phase sequence L1, L2, L3, |
interval length | 10 minutes |
Star connection | (L1, L2, L3 to N) |
Power supply | 88 V ... 265 V AC |
Environment conditions |
Working temp. range | -10°C ... +55 C |
Operating temp. range | 0°C … +35°C |
Storage temp. range | -20°C … +60°C |
Reference temp. range | 23°C ± 2K |
Relative humidity | 10...80 %, no dewing |
Safety | IEC/EN 61010-1 600 V CAT III, 300 V CAT IV, pollution degree 2, double insulation |
Type test voltage | 5.2 kV r.m.s., 50 Hz / 60 Hz, 5 s |
EMC |
Emission | IEC/EN 61326-1, EN55022 |
Immunity | IEC/EN 61326-1 |
Power Supply |
Functional range | 88 V …440 V AC, 50 Hz / 60 Hz 100 V … 400 V DC |
Internal fuse | 630 mA T |
Safety | IEC/EN 61010-1 300 V CAT IV pollution degree 2, double insulation |
Via test leads | in parallel to measuring input (max. 440V) |
Power consumption | max. 7 VA |
Intervals | see table on page 1 |
Events | >13.000 |
Memory model | linear, circular |
Interface | RS 232, 9600...115 000 Baud, automatic Baud rate selection, 3-wire communication |
Dimensions, weight | MEMOBOX 808 A: 282 mm x 216 mm x 74 mm, 2.4 kg MEMOBOX 300 P, A: 170 mm x 125 mm x 55 mm, 1.1 kg |
Measurements |
A/D converter | 16 bit, sample rate: 10.24 kHz |
Anti-aliasing filter | FIR-Filter, fC =4.9 kHz |
Frequency response | Error < 1 % for UN = 230 V for 40 Hz…2500 Hz |
Interval length | 5, 10, 30 s, 1, 5, 10, 15, 60 minutes |
Averaging time for Min/max values | ½, 1 mains period, 200 ms,1 , 3 , 5 s |
Time base | deviation: max. 2s/day at 23°C |
Inputs |
Voltage |
Input range VI P-N | 69 V / 115 V / 230 V / 480 V AC |
Input range VI P-P | 120 V / 200 V / 400 V / 830 V AC |
Max. overload voltage | 1.2 VI |
Input range selection | by job programming in CODAM software |
Connections | P-P or P-N, 1- or 3-phase |
Nominal voltage UN | ≤ 999 kV |
Input resistance | appr. 820kΩ ?per channel |
Intrinsic error | 0.1 % of VI |
Voltage transformer | ratio: <999 kV / VI |
Current measurement with LEM~flex |
Input ranges II |
A, B, C, N | 15 A / 150 A / 1500 A / 3000 A AC |
Measurement range | 0.75 A … 3000 A AC |
Intrinsic error | <2 % of II |
Position influence | max. ±2% of m.v. – for distance conductor to meas. head >30 mm |
Stray field influence | <±2 A AC for Iext=500 A AC and distance to measuring head >200 mm |
Temperature coefficient | < 0.05% / °C |
Transformer ratio | ≤ 999 kA / ≤ II |
Ratio selection | by job programming |
Connection | 3-phase, 3-phase and Neutral 2-phase L1, L3 (2W-meter-method) |
Current measurement with clamps (instrument without sensors) |
Input ranges II |
A, B, C, N | 0.5V nominal, 1.4 Vpeak |
Intrinsic error | <0.3 % of II |
Overload capacity | 10 V AC max. |
Input resistance | appr. 8.2 kΩ |
Transformer ratio | ≤ 999 kA / ≤ II |
Connections | 3-phase, 3-phase and Neutral wire 2-phase L1, L3, (2W-meter-method) |
RMS measurements |
Slow voltage variations |
Measuring values | Mean-value: RMS values averaged over interval length |
Min-, Max-values | Averaging with selectable |
averaging time 0.5 periods to 5 s |
Max-value | Max. r.m.s. value per interval |
Min-value | Min. r.m.s. value per interval |
Current |
Measuring values |
Mean-value | RMS values integrated over interval length |
Max-value | Highest r.m.s. value per interval |
Events |
Dips, swells, interruptions |
Limit value | variable, lower limit: 0…95 % VN upper limit: 105…120 % VN set in CODAM PLUS |
Range | 0...UI + 20 % |
Measuring value | ½ period RMS value |
Intrinsic error | < 2 % of VI |
Response time | ½ mains period (10ms in 50 Hz systems) |
Flicker |
Measuring value | Flicker level (Plt/Pst) according to IEC 61000-4-15 |
Intrinsic error Pst < 5 % of m.v. |
Measuring range Pst | 0.4 … 4 |
Power |
P, Q, S, |P| |
Active power P | as per EN 61036, class 2 |
Reactive power Q | as per EN 61268, class 2 |
Mean- value | averaged over interval length |
Max-value | highest value per interval |
Min-value | smallest value per interval |
Phase error | < 0.5 degrees |
Conditions | conductor centred within clamp/LEM~flex |
Harmonics |
Um, Im, THD V, THD I as per IEC/EN61000-4-7 | 2002 |
Voltage harmonics |
Intrinsic error | for Vm < 3% UN: < 0.15% VN |
for Vm ≥ 3% UN | < 5% Vm |
Current harmonics |
Intrinsic error | for Im < 10% IN: < 0.5% IN |
for Im ≥ 10% IN | < 5% Im |
THD V (MEMOBOX 300 P) |
Intrinsic error at UN | for THD V < 3%: < 1% |
for THD V ≥ 3% | < 5% |
THD V (MEMOBOX 300 A, 808 A) |
Intrinsic error at UN | for THD V < 3%: < 0.15% |
for THD V ≥ 3% | < 5% |
THD I |
Intrinsic error at IE | for THD I < 3%: < 2% |
for THD I ≥ 3% | < 5% |
Statistics |
Frequency | 42 classes for 10 s mean values |
Ripple control signals, |
Interharmonics | 21 classes for 3 s mean values |
Analysis of measurement data |
Programming and analysis with PC software CODAM PLUS. |