AC Current
|
Range |
333: |
0-400.0 A |
334,335,336: |
0-600.00 A |
337: |
0-999.9 A |
|
Accuracy |
333, 334, 335: |
2% ± 5 counts (50/60 Hz) |
336, 337: |
2% ± 5 counts (10-100 Hz) |
|
6% ± 5 counts(100-400 Hz) |
|
Crest Factor |
333, 334: |
Not Applicable |
335: |
2.4@500 A, 2.0@600 A add 2% for CF>2 |
336: |
3@500 A, 2.5@600 A add 2% for CF>2 |
337: |
3@500 A 2.5@600 A 1.42@1000 A add 2% for CF>2 |
|
AC Response |
333, 334: |
Averaging |
335, 336, 337: |
True-rms |
|
|
In-Rush |
Integration Time |
333: |
Not Applicable |
334, 335, 336, 337: |
100 ms |
|
|
DC Current
|
Range |
333, 334, 335: |
Not Applicable |
336: |
0-600.0 A |
337: |
0-999.9 A |
|
Accuracy |
333, 334, 335: |
Not Applicable |
336, 337: |
2% ± 3 counts |
|
|
AC Volts
|
Range |
333, 334, 335, 336, 337: |
0-600.0 V |
|
Accuracy |
333, 334, 335: |
1% ± 5 counts (50/60 Hz) |
336, 337: |
1% ± 5 counts (20-100 Hz), 6% ± 5 counts (100-400 Hz) |
|
AC Response |
333, 334: |
Averaging |
335, 336, 337: |
True-rms |
|
|
DC Volts
|
Range |
333, 334, 335, 336, 337: |
0-600.0 V |
|
Accuracy |
333, 334, 335, 336, 337: |
1% ± 5 counts |
|
|
Resistance
|
Range |
333: |
0-600.0 Ω |
334, 335, 336, 337: |
0-600.0 Ω, 601-6000 Ω |
|
Accuracy |
333, 334, 335, 336, 337: |
1.5% ± 5 counts |
|
|
Continuity |
|
333, 334, 335, 336, 337: |
≤30 Ω |
|
|
Frequency
(AC Only)
|
Range |
333, 334, 335, 336: |
Not Applicable |
337: |
0-600.0 Ω, 601-6000 Ω |
|
Accuracy |
333, 334, 335, 336: |
Not Applicable |
337: |
5-400 Hz |
|
Trigger Level |
333, 334, 335, 336: |
0.5% ± 5 counts |
337: |
10-100 Hz > 5 A 5-10 Hz, 100-400 Hz > 10 A |
|
|