| Key features |
TiS20+ |
| Infrared resolution |
120 x 90 (10,800 pixels) |
| IFOV (spatial resolution) |
7.6 mRad, D:S 130:1 |
| Field of view |
50° H x 38° V |
| Minimum focus distance |
50cm (20 inches) |
| Focus system |
Fixed focus |
| Data transfer |
Mini USB used to transfer image to PC |
| Wireless connectivity |
Yes, (802.11 b/g/n (2.4 GHz)) |
| Fluke Connect instant upload |
Yes, connect your camera to your building’s WiFi network (802.11 b/g/n (2.4 GHz)), and images taken automatically upload to the Fluke Connect system or your local server for storage and viewing on your PC |
| Image quality |
| Level and span |
Smooth auto and manual scaling |
| IR-Fusion technology |
AutoBlend continuous 0 % to 100 %. Adds the context of the visible details to your infrared image |
| Display |
3.5" LCD touchscreen (landscape) |
| Display resolution |
320 x 240 LCD |
| Thermal sensitivity (NETD) |
60 mK |
| Frame rate |
9 Hz |
| Data storage and image capture |
| Memory |
Internal 4GB memory (includes slot for optional micro SD card up to 32GB) |
| Image capture, review, save mechanism |
One-handed image capture, review, and save capability |
| Image file formats |
Non-radiometric (jpeg), or fully radiometric (.is2); no analysis software required for non-radiometric (jpeg) files |
| Software |
Fluke Connect desktop software—full analysis and reporting software with access to the Fluke Connect system |
| Export file formats with software |
.bmp, .dib, .jpg, .tif, .tiff |
| Battery |
| Batteries (field-replaceable, rechargable) |
Lithium ion smart battery pack with five-segment LED display to show charge level |
| Battery life |
≥ 5 hours continuous (without WiFi) |
| Battery charging time |
2.5 hours to full charge |
| Battery charging system |
In-imager charging. Optional 12 V automotive charging adapter |
| AC operation |
AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
| Power saving |
Automatic Shutdown: 5, 10, 15 and 20 minutes or never |
| Temperature measurement |
| Temperature measurement range (not calibrated below 0 °C) |
-20 °C to 150 °C (-4°F to 302°F) |
| Accuracy |
Target temp at or over 0 °C: Accuracy: ± 2 °C or ± 2 % at 25 °C, whichever is the greater. |
| On-screen emissivity correction |
Yes, material table |
| On-screen reflected background temperature compensation |
Yes |
| Center-point temperature |
Yes |
| Spot temperature |
Hot and cold spot markers |