TiX560 |
TiX520 |
IFOV with standard lens (spatial resolution) |
1.31 mRad |
Detector resolution
|
320 x 240 (76,800 pixels) |
Field of view
|
24 °H x 17 °V |
Minimum focus distance
|
15 cm (approx. 6 in) |
IFOV with optional telephoto lens |
0.65 mRad |
Field of view
|
12 °H x 9 °V |
Minimum focus distance
|
45 cm (approx. 18 in) |
IFOV with optional wide-angle lens |
2.62 mRad |
Field of view
|
46 °H x 34 °V |
Minimum focus distance
|
15 cm (approx. 6 in) |
SuperResolution* |
On camera and in software |
In software |
Image sharpening |
Yes |
No |
LaserSharp® Auto Focus |
Yes, for consistently in-focus images. Every. Single. Time. |
Laser distance meter |
Yes, calculates distance to the target for precisely focused images and displays distance on screen |
Advanced manual focus |
Yes |
Streaming video (remote display) |
Via USB or WiFi |
Touchscreen display (capacitive) |
14.4 cm (5.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight |
Wireless connectivity |
Yes |
Wireless compatibility
|
Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available) |
Fluke Connect™ app compatible
|
Yes (where available) |
Fluke Connect™ tool compatible
|
Yes (where available). Connects wireless to select Fluke Connect™ enabled tools. Five simultaneous connections supported |
IR-Fusion® technology |
|
AutoBlend™ mode
|
Yes |
Picture-In-Picture (PIP)
|
Yes |
Continuous AutoBlend™
|
Set AutoBlend™ level across continuum |
No |
Rugged, ergonomic design |
Rotatable (articulating lens) >180 degrees |
Thermal sensitivity (NETD) |
≤ 0.045 °C at 30 °C target temp (45 mK) |
≤ 0.05 °C at 30 °C target temp (50 mK) |
Filter Mode (NETD improvement) |
≤ 0.03 °C at 30 °C target temp (30 mK) |
≤ 0.04 °C at 30 °C target temp (40 mK) |
Level and span |
Smooth auto and manual scaling |
Touchscreen adjustable level / span
|
Yes. Span and level can be easy and quickly set by simply touching the screen |
Fast auto toggle between manual and auto modes
|
Yes |
Fast auto-rescale in manual mode
|
Yes |
Minimum span (in manual mode)
|
2.0 °C (3.6 °F) |
Minimum span (in auto mode)
|
3.0 °C (5.4 °F) |
Built-in digital camera (visible light) |
5 megapixel industrial performance |
Frame rate |
60 Hz or 9 Hz versions |
Laser pointer |
Yes |
LED light (torch) |
Yes |
Digital Zoom |
2x, 4x, 8x |
2x, 4x |
Extensive memory options |
Removable micro SD memory card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection |
Image capture, review, save mechanism |
One-handed image capture, review, and save capability |
Post-capture Image Editing (on camera) |
Yes. Conduct on camera analysis for in-field results |
Advanced text Annotation |
Yes. Including standard shortcuts as well as user programmable options |
File formats |
Non-radiometric (.bmp) or (.jpeg) or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files |
Memory review |
Thumbnail view navigation and review selection |
Software |
SmartView® software, Fluke Connect™ (where available), and SmartView® Mobile App—full analysis and reporting software |
Export file formats with SmartView®
software |
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Voice annotation |
60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset provided* |
IR-PhotoNotes™ |
Yes |
Text annotation |
Yes |
Video recording |
Standard and radiometric |
File formats video |
Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3) |
Remote control and operation (for special and
advanced applications) |
Yes |
No |
Auto capture (temperature and interval) |
Yes |
Batteries (field-replaceable, rechargeable) |
Two lithium ion smart battery packs with five-segment LED display to show charge level |
Battery life |
Three hours continuous use per battery pack |
Battery charge time |
2.5 hours to full charge |
Battery charging system |
Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter |
AC operation |
AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Power saving |
User selectable sleep and power off modes |
Temperature measurement range (not calibrated
below -10 °C) |
-20 °C to +1200 °C (-4 °F to +2192 °F) |
-20 °C to +850 °C (-4 °F to +1562 °F) |
Accuracy |
± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction |
Yes (both value and table) |
On-screen reflected background temperature
compensation |
Yes |
On-screen transmission correction |
Yes |
Standard palettes |
8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast™ palettes |
8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale
Inverted Ultra |
Color alarms (temperature alarms) |
High-temperature and low-temperature |
Infrared spectral band |
7.5 m to 14 m (long wave) |
Operating temperature |
-10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature |
-20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity |
10 % to 95 % non-condensing |
Center-point temperature measurement |
Yes |
Spot temperature |
Hot and cold spot markers |
User-definable spot markers |
3 user-definable spot markers |
Center box |
Expandable-contractible measurement box with MIN-MAX-AVG temp |
Safety |
IEC 61010-1: Overvoltage Category II, Pollution degree 2 |
Electromagnetic compatibility |
IEC 61326-1: Basic EM Environment
CISPR11, Group 1, Class A
|
Australian RCM |
IE 61326-1 |
US FCC |
CFR 47, Part 15 Subpart B |
Vibration |
0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6 |
Shock |
25 g, IEC 68-2-29 |
Drop |
Engineered to withstand 1 meter (3.3 feet) drop with standard lens |
Size (H x W x L) |
27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in) |
Weight (battery included) |
1.54 kg (3.4 lb) |
Enclosure rating |
IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty |
Two-years (standard), extended warranties are available |
Recommended calibration cycle |
Two-years (assumes normal operation and normal aging) |
Supported languages |
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese,
Spanish, Swedish, Traditional Chinese, and Turkish |