TiS65 |
TiS60 |
TiS55 |
TiS50 |
TiS45 |
TiS40 |
TiS20 |
TiS10 |
IFOV (spatial resolution) |
2.4 mRad |
2.8 mRad |
3.9 mRad |
5.2 mRad |
7.8 mRad |
Detector resolution |
260 x 195 |
220 x 165 |
160 x120 |
120 x 90 |
80 x 60 |
Field of view |
35.7° x 26.8° |
Distance-to-Spot |
417:1 |
353:1 |
257:1 |
193:1 |
128:1 |
Wireless connectivity |
Yes |
Fluke Connect® app compatible |
Yes (where available) |
IR-Fusion® technology |
AutoBlend™ mode |
5 presets (0 %, 25 %, 50 %, 75 %, 100 %) |
3 presets
(0 %, 50 %, 100 %) |
— |
Picture-In-Picture (PIP) |
5 presets (0 %, 25 %, 50 %, 75 %, 100 % |
— |
Focus system |
Manual focus, Minimum focus distance, 0.15 m (6 in) |
Fixed focus, Minimum focus distance 0.45 m (1.5 ft) |
Manual focus, Minimum focus distance, 0.15 m (6 in) |
Fixed focus, Minimum focus distance 0.45 m (1.5 ft) |
Manual focus, Minimum focus distance, 0.15 m (6 in) |
Fixed focus, Minimum focus distance 0.45 m (1.5 ft) |
Ruggedized display |
3.5 inch (landscape) 320 x 240 LCD |
Rugged, ergonomic design for one-handed use |
Yes |
Thermal sensitivity (NETD) |
≤ 0.08 °C at 30 °C target temp (80 mK) |
≤ 0.09 °C at 30 °C target temp (90 mK) |
≤ 0.10 °C at 30 °C target temp (100 mK) |
≤ 0.15 °C at 30 °C target temp (150 mK) |
Temperature measurement range (not calibrated below -10 °C) |
-20 °C to +550 °C (–4 °F to 1022 °F) |
-20 °C to + 450 °C (–4 °F to 842 °F) |
-20 °C to +350 °C (–4 °F to 662 °F) |
-20 °C to +250 °C (–4 °F to 482 °F) |
Level and span |
Smooth auto and manual scaling |
Fast auto toggle between manual and automodes |
Yes |
Fast auto-rescale in manual mode |
Yes |
Minimum span (in manual mode) |
2.5 °C |
Minimum span (in auto mode) |
5 °C |
Built-in digital camera (visible light) |
5MP |
Frame rate |
9 Hz or 30 Hz |
9 Hz |
9 Hz or 30 Hz |
9 Hz |
9 Hz or 30 Hz |
9 Hz |
Laser pointer |
Yes |
— |
Data storage and image capture |
Extensive SD memory system |
Internal 4GB memory and 4GB micro SD card |
Internal 4GB memory (optional 4GB micro SD card sold separately) |
Image capture, review, save mechanism |
One-handed image capture, review, and save capability |
Image file formats |
Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2);
No analysis software required for non-radiometric (.bmp, .jpg) files
|
Instant Upload |
Upload captured images to Fluke Connect server with the use of a Wifi connection |
Memory review |
Thumbnail review |
Software |
SmartView® software -full analysis and reporting software and Fluke Connect® (where available) |
Export file formats with SmartView®software |
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Voice annotation |
Yes, Bluetooth Headset (sold separately) |
— |
IR-PhotoNotes™ |
Yes (3 images) |
Yes (1 image) |
— |
Standard video recording |
Yes |
— |
Radiometric video recording |
Yes |
— |
Video file formats |
Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3) |
— |
Battery |
Batteries (field-replaceable, rechargeable) |
Two lithium ion smart battery packs with five-segment LED display to show charge level |
One lithium ion smart battery packs with five-segment LED display to show charge level |
Battery life |
Battery charge time |
2.5 hours to full charge |
Battery charging system |
Two-bay battery charger or in- imager charging |
In-imager charging (optional external charger sold separately) |
AC operation |
AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Temperature measurement |
Accuracy |
± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction |
Yes (both value and table) |
On-screen reflected background temperature compensation |
Yes |
On-screen transmission correction |
Yes |
Color palettes |
Standard palettes |
8: Ironbow, Blue-Red, High-Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
7: Ironbow, Blue-Red, High-Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
6: Ironbow, Blue-Red, High-Contrast, Amber, Hot Metal, Gray-scale |
3: Ironbow, Blue-Red, Grayscale |
Ultra Contrast™ palettes |
8: Ironbow Ultra, Blue-Red Ultra, High-Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
— |
Color alarms (temperature alarms |
High temperature, low temperature, Isotherms |
High temperature, low temperature |
— |
Infrared spectral band |
7.5 μm to 14 μm |
Operating temperature |
-10°C to +50°C (14°F to 122°F) |
Storage temperature |
-20°C to +50°C (-4°F to 122°F) |
Relative humidity |
10 % to 95 %, non-condensing |
Center-point temperature measurement |
Yes |
— |
Spot temperature |
Yes |
User-definable spot markers |
3 |
2 |
1 |
— |
Center box |
Expandable-contractible measurement box with MIN-MAX-AVG temp |
— |
Safety standards |
EN 61010-1: CAT none, pollution degree 2, EN 60825-1: Class 2, EN 60529, EN 62133 (lithium battery) |
Electromagnetic compatibility |
EN 61326-1:2006, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3 |
C Tick |
IEC/EN 61326-1 |
US FCC |
EN61326-1; FCC Part 5, EN 55011: Class A, EN 61000-4-2 |
Vibration and Shock |
2G, IEC 68-2-6 and 25G, IEC 68-2-29 |
Drop |
Engineered to withstand 2 meter (6.5 feet) drop |
Size (H x W x L) |
26.7 cm x 10.1 cm x 14.5 cm (10.5 in x 4.0 in x 5.7 in) |
Weight (battery included) |
Fixed Focus .72 kg (1.6 lb), Manual focus .77 kg (1.7 lb) |
Enclosure rating |
IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty |
Two-years (standard), extended warranties are available |
Recommended calibration cycle |
Two-years (assumes normal operation and normal aging) |
Supported languages |
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |