General Specifications |
|
Ti401 PRO |
Ti450 PRO |
Key features |
Detector resolution |
640 x 480 (307,200 pixels) |
320 x 240 (76,800 pixels) or 640 x 480 with SuperResolution |
SuperResolution |
No |
Yes, in software. Captures and combines 4x the data to create a 640 x 480 image |
IFOV with standard lens (spatial resolution) |
0.93 mRad, D:S 1065:1 |
1.31 mRad, D:S 753:1 |
Field of view |
34 °H x 24 °V |
24 °H x 17 °V |
Minimum focus distance |
15 cm (approx. 6 in) |
MultiSharp™ Focus |
No |
Yes, focused near and far, throughout the field of view |
LaserSharp® Auto Focus |
Yes, for consistently in-focus images. Every. Single. Time. |
Laser distance meter |
Yes, calculates distance to the target for precisely focused images and displays distance on screen |
Advanced manual focus |
Yes |
Wireless connectivity |
Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available) |
Fluke Connect® app compatible |
Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing |
Fluke Connect® Assets optional software |
Yes*, assign images to assets and create work orders. Easily compare measurement types in one location. |
Fluke Connect® Instant Upload |
Yes*, connect your camera to your building’s WiFi network, and images taken automatically upload to the Fluke Connect system for viewing on your smartphone or PC |
Fluke Connect® Instant Server Upload |
Yes* |
IR-Fusion® technology |
Yes, adds the context of the visible details to your infrared image |
Ruggedized touchscreen display |
3.5 inch (landscape) 640 x 480 LCD |
Thermal sensitivity (NETD)** |
≤ 0.075 °C at 30 °C target temp (75 mK) |
≤ 0.025 °C at 30 °C target temp (25 mK) |
Level and span |
Smooth auto and manual scaling |
Fast auto toggle between manual and auto modes |
Yes |
Fast auto-rescale in manual mode |
Yes |
Minimum span (in manual mode) |
2.0 °C (3.6 °F) |
Minimum span (in auto mode) |
3.0 °C (5.4 °F) |
Built-in digital camera (visible light) |
5MP |
Frame rate |
60 Hz or 9 Hz versions |
Laser pointer |
Yes |
LED light (torch) |
Yes, improved output torch |
Digital zoom |
No |
2x and 4x |
Data storage and image capture |
Extensive memory options |
Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload to for permanent storage |
Image capture, review, save mechanism |
One-handed image capture, review, and save capability |
Image file formats |
bmp, jpeg, is2 |
Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files |
Memory review |
Thumbnail and full screen review |
Software |
SmartView® software—full analysis and reporting software |
Export file formats with Fluke Connect® desktop software |
Bitmap (.bmp), GIF, JPEG, PNG, TIFF |
Voice annotation |
60 seconds maximum recording time per image; reviewable playback on camera, optional bluetooth headset available but not required |
IR-PhotoNotes |
Yes (2 images) |
Yes (5 images) |
Text annotation |
Yes |
Video recording |
No |
Standard and radiometric |
Remote control operation |
Remote display through Fluke Connect |
Yes, through SmartView® software or Fluke Connect® mobile app |
Auto capture (temperature and interval) |
No |
Yes |
Battery |
Batteries (field-replaceable, rechargeable) |
Two lithium ion smart battery packs with five-segment LED display to show charge level |
Battery life |
2-3 hours per battery (*Actual life varies depending on settings and usage) |
3-4 hours per battery (*Actual life varies depending on settings and usage) |
Battery charge time |
2.5 hours to full charge |
Battery charging system |
Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter |
AC operation |
AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Power saving |
User selectable sleep and power off modes |
*Fluke Connect analysis and reporting software is available in all countries but Fluke Connect is not. Please check availability with your authorized Fluke distributor.
** Best possible |
|
Ti401 PRO |
Ti450 PRO |
Temperature measurement |
Temperature measurement range (not calibrated below -10 °C) |
-20 °C to +650 °C (-4 °F to +1,202 °F) |
-10 °C to 1500 °C (14 °F to 2732 °F) |
Accuracy |
± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction |
Yes (both value and table) |
On-screen reflected background temperature compensation |
Yes |
On-screen transmission correction |
Yes |
Live line marker |
No |
Yes |
Color palettes |
Standard palettes |
9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast palettes |
9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Specification |
Color alarms (temperature alarms) |
High temperature, low temperature, and isotherms (within range) |
Infrared spectral band |
7.5 μm to 14 μm (long wave |
Operating temperature |
-10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature |
-20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity |
10 % to 95 % non-condensing |
Center-point temperature measurement |
Yes |
Spot temperature |
Hot and cold spot markers |
User-definable spot markers |
No |
3 user-definable spot markers |
Center box |
1 expandable-contractible measurement box with MIN-MAX-AVG temp display |
Up to 3 expandable-contractible measurement box with MIN-MAX-AVG temp display |
Safety |
IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
Electromagnetic compatibility |
IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A |
Australian RCM |
IEC 61326-1 |
US FCC |
CFR 47, Part 15 Subpart C Sections 15.207, 15.209, 15.249 |
Vibration |
0.03 g2/Hz (3.8 g), 2.5 g IEC 68-2-6 |
Shock |
25 g, IEC 68-2-29 |
Drop |
Engineered to withstand 2 meter (6.5 feet) drop with standard lens |
Size (H x W x L) |
27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in) |
Weight (battery included |
1.04 kg (2.3 lb) |
Enclosure rating |
IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty |
Two-years (standard), extended warranties are available |
Recommended calibration cycle |
Two-years (assumes normal operation and normal aging) |
Supported languages |
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
RoHS compliant |
Yes |