Fluke Calibration Platinum Resistance Thermometers (PRTs) |
Model |
Range |
Size |
Basic Accuracy† |
5608-9-X |
–200 to 500 °C |
9 in x 1/8 in |
Select from available calibration options |
5608-12-X |
–200 to 500 °C |
12 in x 1/8 in |
5609-12-X |
–200 to 670 °C |
12 in x 1/4 in |
5609-15-X |
–200 to 670 °C |
15 in x 1/4 in |
5609-20-X |
–200 to 670 °C |
20 in x 1/4 in |
5609-300-X |
–200 to 670 °C |
300 mm x 6 mm |
5609-400-X |
–200 to 670 °C |
400 mm x 6 mm |
5609-500-X |
–200 to 670 °C |
500 mm x 6 mm |
5626 |
–200 °C to 661 °C |
305 or 381 x 6.35 mm (12 or 15 x 0.25 in |
±0.007 °C at 0 °C |
5616-12 |
–200 °C to 420 °C |
6.35 mm x 298 mm (0.250 x 11.75 in) |
± 0.010 °C at 0.010 °C |
5615-6 |
–200 to 300 °C |
4.76 mm x 152 mm (0.188 x 6.0 in) |
± 0.013 °C at 0.010 °C |
5615-9 |
–200 °C to 420 °C |
4.76 mm x 229 mm (0.188 x 9.0 in) |
± 0.013 °C at 0.010 °C |
>5615-12 |
–200 °C to 420 °C |
6.35 mm x 305 mm (0.250 x 12.0 in) |
± 0.013 °C at 0.010 °C |
5627A-6 |
–200 °C to 300 °C |
152 x 4.7 mm (6 x 0.187 in) |
±0.05 °C at 0 °C |
5627A-9 |
–200 °C to 300 °C |
229 x 4.7 mm (9 x 0.187 in) |
±0.05 °C at 0 °C |
5627A-12 |
–200 °C to 420 °C |
305 x 6.35 mm (12 x 0.25 in) |
±0.05 °C at 0 °C |
>5622-05 |
–200 °C to 350 °C |
100 x 0.5 mm |
±0.04 °C at 0 °C |
>5622-10 |
–200 °C to 350 °C |
100 x 1.0 mm |
±0.04 °C at 0 °C |
>5622-16 |
–200 °C to 350 °C |
200 x 1.6 mm |
±0.04 °C at 0 °C |
>5622-32 |
–200 °C to 350 °C |
200 x 3.2 mm |
±0.04 °C at 0 °C |
5618B-6 |
–200 °C to 300 °C |
152 x 3.2 mm (6 x 0.125 in) |
±0.05 °C |
5618B-9 |
–200 °C to 500 °C |
229 x 3.2 mm (9 x 0.125 in) |
±0.05 °C |
5618B-12 |
–200 °C to 500 °C |
305 x 3.2 mm (12 x 0.125 in) |
±0.05 °C |
5606 Immersion PRT |
–200 to 160 °C |
50 x 3.1 mm ( 2 x 1/8 in) |
±0.05 °C |
5607 Immersion PRT |
0 to 450 °C |
75 x 3.1 mm (3 x 1/8 in) |
±0.055 °C |
5623B Freezer Probe |
–100 °C to 156 °C |
152 x 6.35 mm (6 x 0.25 in) |
±0.05 °C |
5640 |
0 °C to 60 °C |
229 x 6.35 mm (9 x 0.25 in) |
±0.0015 °C |
5641 |
0 °C to 60 °C |
114 x 3.2 mm (4.5 x 0.125 in) |
±0.001 °C |
5642 |
0 °C to 60 °C |
229 x 3.2 mm (9 x 0.125 in) |
±0.001 °C |
5643 |
0 °C to 100 °C |
114 x 3.2 mm (4.5 x 0.125 in) |
±0.0025 °C |
5644 |
0 °C to 100 °C |
229 x 3.2 mm (9 x 0.125 in) |
±0.0025 °C |
5610 |
0 °C to 100 °C |
152 or 229 x 3.2 mm (6 or 9 x 0.125 in) |
±0.01 °C |
5611A |
0 °C to 100 °C |
1.5 mm (0.06 in) tip dia. |
±0.01 °C |
5611T |
0 °C to 100 °C |
28 x 3 mm (1.1 x 0.12 in) |
±0.01 °C |
†“Basic Accuracy” includes calibration uncertainty and short-term repeatability. It does not include long-term drift.
X = termination. Specify A (INFO-CON for 914X), B (bare wire), D (5-pin DIN for Tweener Thermometers), G (gold pins), I (INFO-CON for 1521 or 1522), J (banana plugs), L (mini spade lugs), M (mini banana plugs), P (INFO-CON for 1523 or 1524), or S (spade lugs). |