Typical range [1] |
0.2-40 m/0.6-131 ft |
Typical measuring tolerance* [1] |
2.0 mm ± 1.5 mm/± 0.06 in *** |
Maximum measuring tolerance [2] |
± 3.0 mm/0.12 in *** |
Accuracy up to 10m (+/-) |
± 2 mm |
Display |
2 line/1 mm/1/32 in |
Display illumination |
Yes |
Laser point at distance |
6/30/60 mm (10/40/100 m) |
Area |
Yes |
Units setting (smallest units displayed) |
0,000m, 0' 00'' 1/32, 0 in 1/32 |
Auto laser switch off |
90 sec |
Auto power switch off |
180 sec |
Laser class |
II |
Laser type |
635 nm, <1 mW |
Protection class |
IP54 |
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 |
Up to 3,000 measurements |
Size (Hx W x D) |
11.9 x 3.8 x 2.6 cm |
Drop tes |
1 meter |
Weight (with batteries) |
95g (3.35 oz) |
Temperature range: Storage |
-25 °C to 70 °C (-13 °F to 158 °F) |
Temperature range: Operation |
-10 °C to 50 °C (14 °F to 122 °F) |
Calibration cycle |
Not applicable |
Maximum relative humidity |
85 % @ 20°F to 120 °F
(-7 °C to 50 °C) |
Safety |
CAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA82.02.01, IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II) |
EMC |
61326-1:2006 |
Temperature range |
- 30 °C to 650 °C
(-22 °F to 1202 °F) |
Accuracy (Calibration geometry with ambient temperature 23 °C +/- 2 °C) |
ą 1.0 °C or ą 1.0 % of reading, whichever is greater
ą 2.0 °C at -10 °C to 0 °C
ą 3.0 °C at -30 °C to -10 °C |
Optical resolution |
12:1
(calculated at 90 % energy) |
Response time (95 %) |
< 300 ms (95 % of reading) |
Spectral response |
8 to 14 microns |
Emissivity |
0.10 to 1.00 |
Display resolution |
0.1 °C (0.2 °F) |
Repeatability (% of reading) |
ą 0.5 % of reading or ą 0.5 °C (whichever is greater) |
Power |
1 AA alkaline battery |
Battery life |
8 hours with laser and backlight on |
Weight |
255 g (8.99 oz) |
Size |
(175 x 85 x 75) mm
(6.88 x 3.34 x 2.95) inches |
Operating temperature |
0 °C to 50 °C
(32 °F to 122°F) |
Storage temperature |
-20 °C to 60 °C
(-4 °F to 140 °F)
(without battery) |
Operating humidity |
Non- condensing @ ≤ 10 °C (50 °F)
≤ 90 % RH @ 10 °C (50 °F) to 30 °C (86 °F)
≤ 75 % RH @ 30 °C (86 °F) to 40 °C (104 °F)
≤ 45 % RH @ 40 °C (104 °F) to 50 °C (122 °F) |
Operating altitude |
2000 meters above mean sea level |
Storage altitude |
12,000 meters above mean sea level |
Drop test |
3 meters |
Implement standard |
Q/ASF01 |
Compliance |
IEC 61010-1: Pollution Degree 2 |
Laser safety |
IEC 60825-1 Class 2, 650 nm, < 1 mW |
Ingress protection rating |
IP 54 per IEC 60529 |
Warranty |
3 years |
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C (13 °F).
[2] Applies for 10 % to 500 % target reflectivity, high background illumination, -10 °C to +50 °C (14 °F to +122 °F).
[3] Tolerances apply from 0.05 m to 10 m (0.001 ft to 32.8 ft) with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m (0.003 in/ft) between 10 m to 30 m (32.8 ft to 98.4 ft) and to 0.15 mm/m (0.005 in/ft) for distances above 30 m (98.4 ft).
[4] Applies for 100 % target reflectivity, background illumination between 10,000 lux and 30,000 lux.
[5] After user calibration. Additional angle related deviation of ± 0.01° per degree upto ± 45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ± 0.1° |