Physical Specifications |
Dimensions (H,W,D) |
9.45" x 12.43" x 2.03" (240 mm x 315.7 mm x 51.6 mm) |
Weight |
5.6 lb. (2.5 kg) with batteries; 4.5 lb. (1.8 kg) without batteries |
Display |
Color active matrix TFT LCD, 1024 x 768 pixels, LED backlight, touch panel with 2 touch points |
Security |
Kensington® security slot on rear panel for connection of security cable |
Environmental Specifications |
Operating Temperature |
10°C to 30°C (50°F to 86°F) with up to 95% Relative Humidity. 0°C to 50°C (32°F to 122°F) with up to 75% Relative Humidity |
Storage Temperature |
-40°F to +160°F (-40°C to +71°C) |
Shock and Vibration |
Meets requirements of MIL-PRF-28800F for Class 3 equipment |
Safety |
EN 61010-1 2nd Edition |
Altitude |
4600 m (15000 ft) on batteries |
Electrical Specifications |
AC Adapter Input |
100 V – 240 V, 50/60 Hz, 1.5 A |
AC Adapter Output |
19 VDC, 4.74 A, 90 W |
Battery |
Two user-replaceable, rechargeable, 45 Watt-hour, lithium-ion battery packs. |
Battery Operating Time |
2 hr. (typical - can be extended to approximately four hours by disabling/powering down the network under test ports for doing extended WLAN analysis) |
Battery Charge Time |
3 hr. (typical). Charge time depends on residual battery charge |
System Specifications |
Operating System |
Window 7 Professional, 64 Bit, Service Pack 1 |
PC - Processor |
Intel® Core™ Duo CPU U9300 @ 1.2GHz |
PC - RAM |
4 GB |
Capture Buffer |
4 GB |
Wired Network Connection Specifications |
Ports |
Network Analysis Ports |
2 RJ-45 10/100/1000BASE-T Ethernet, Small form-factor pluggable (SFP) 100/1000BASE-X Ethernet, enhanced small form-factor pluggable (SFP+) 10GBASE-X Ethernet |
Management Port |
RJ-45 10/100/1000BASE-T Ethernet |
Supported SFP Modules |
1000BASE-SX - 850 nm (Standard)
100BASE-FX - 1300 nm
1000BASE-LX - 1310 nm
1000BASE-ZX - 1550 nm |
Supported SFP+ Modules |
10GBASE-SR - 850 nm (Standard)
10GBASE-LR - 1310 nm
10GBASE-LRM - 1310 nm |
Fault Tolerance |
RJ-45 Ports are designed to withstand a maximum of 100 volts |
USB Ports |
Three USB 2.0 ports |
eSATA Port |
eSATA port for connecting external hard drive |
Video Port |
Standard VGA port for connection to monitor or projector |
Cables |
Cable Types |
100 Ohm UTP and ScTP category 5, 5E, 6, ISO/IEC Class C, D, E |
Cable Length Measurement |
Measurable cable lengths are from 3 feet (0.9 meters) to 500 feet (152 meters)
Accuracy: ± 6 feet (± 2 meters)
Length measurement is based on Nominal Velocity of Propagation (NVP) for selected cable type |
Wireless Network Connection Specifications |
Wireless Antennas |
Internal Wireless Antennas |
Seven internal 2.4 GHz, 1.1 dBi peak, 5 GHz,
3.2 dBi peak antennas |
External Omni-directional Antenna |
Antenna, WLAN, omnidirectional, 2.4 & 5 GHz
802.11 A/B/G, 50 Ω. Gain: 2.1 dBi (2.45 GHz)
2.4 dBi (4.9 GHz), 2.6 dBi (5.25 GHz), 2.5 dBi (5.875 GHz) |
External Directional Antenna |
Antenna, frequency range 2.4 - 2.5 and 4.9 - 5.9 GHz
Minimum gain 5.0 dBi peak in the 2.4 GHz band, and 7.0 dBi peak in the 5 GHz band |
External Antenna Connector |
Reverse SMA |
Wireless Adapters |
Data Rate |
11a: 6/9/12/24/36/48/54 Mbps
11b: 1/2/5.5/11 Mbps
11g: 6/9/12/24/36/48/54 Mbps
11n (20 MHz): MCS0-23, up to 216 Mbps
11n (40 MHz): MCS0-23, up to 450 Mbps |
Operating Frequency |
2.4000 ~ 2.472 GHz (Industrial Scientific Medical Band) 5.180 ~ 5.825 GHz |
Security |
64/128-Bit WEP Key, WPA, WPA2, 802.1x |
Transmit Output Power (Tolerance |
±1.5 dBm): 802.11b: 18 dBm
802.11b: 18 dBm
802.11g: 17 dBm
802.11a: 11 dBm
802.11n: 2.4 GHz:17 dBm
802.11n: 5 GHz:13 dBm |
Receive Sensitivity (Tolerance |
±2 dBm): 802.11a: 10% PER -78 dBm
802.11b: 8% PER -90 dBm
802.11g: 10% PER -80 dBm
802.11n: 2.4 GHz 10% PER
-72 dBm@HT20
-70 dBm@HT40
802.11n: 5 GHz 10% PER
-70 dBm@HT20
-63 dBm@HT40 |
Power Consumption (Typical ) |
Transmitting (Legacy mode, HT20 mode): 870 mA @5 GHz, 700 mA @2.4 GHz
Transmitting (HT40 mode): 900 mA @5 GHz, 750 mA @2.4 GHz
Receiving (Legacy mode, HT20 mode): 550 mA @5 GHz, 520 mA @2.4 GHz
Receiving (HT40 mode): 610 mA @5 GHz, 600 mA @2.4 GHz |
Compliance Statements |
EMC |
Complies with IEC/EN61326-1:2006, class A |
Safety |
Complies with IEC/EN 61010-1:2001, CAN/CSA C22.2 No. 61010-1-04, ANSI/UL 61010-1:2004, EN/IEC 60825-1:2007, EN/IEC 60825-2:2004+ A1:2007 |
Telephone* |
The OptiView XG is NOT designed for connection to a telephone network
The OptiView XG is NOT designed for connection to an ISDN line |