Operating temperature with the battery |
0ºC to 50ºC |
Non-operating temperature |
-20ºC to 60ºC |
Operating relative humidity (without condensation) |
95% (10ºC to 35ºC) 75% (35ºC to 40ºC) uncontrolled < 10ºC |
Vibration |
Random, 5 Hz to 500 Hz, MIL-PRF-28800F CLASS 2 |
Shock |
1 meter drop test |
Altitude |
3000m |
EMC |
EN 61326-1: 2004 |
Battery type |
2 AA alkaline batteries (no battery charger) |
Battery life |
1500 tests (typical) |
Laser safety |
Class 1 CDRH Complies to EN 60825-2 |
LCD type |
Backlit black and white (segments) |
Index of refraction range |
1.45 to 1.5 (factory default is 1.496) |
Auto turn off |
Automatically turns off after 5 minutes if no keys are pressed. Backlight turns off first. |
Factory calibration interval |
None |
Output wavelengths |
850 nm ± 10 nm |
Laser classification |
Class 1 CDRH Complies to EN 60825-2 |
Dynamic range |
>11 dB |
Maximum distance |
1500 meters or 4921 feet |
Maximum number of incidents shown |
9 |
Distance accuracy (0 m to 1500 m or 0 ft to 4921 ft) |
± (1 m + 0.1 % x length) for reflective incidents1 ± (3 m + 0.1 % x length) for non-reflective incidents2 |
Testing speed |
< 6 seconds typical |
Connector |
Removable/cleanable SC adapter, UPC polish |
Fiber types tested |
50/125 µm or 62.5/125 µm multimode |
Detection of reflective incidents3 |
-35 dB default threshold (User selectable: -20 dB to -45 dB in 5 dB increments) |
Reflectance accuracy4 |
± 4 dB |
Maximum reflectance measurement |
-20 dB |
Detection of loss incidents5 |
0.70 dB default threshold (user-configurable from 0.5 dB to 6.1 dB in 0.2 dB increments) |
Bulkhead quality |
If no fiber is attached or if the connector is dirty, the troubleshooter displays 0 m or 0 ft. |
Live fiber detection |
Detects optical signals from 600 nm to 1050 nm and shows ACTIVE LINE if a signal is there. Looks for a signal every 3 seconds after the first detection. +7 dB maximum input power. |
Certifications and compliance |
Conforms to relevant European Union directives
Conforms to relevant Australian standards
Listed by the Canadian Standards Association CSA C22.2 No. 61010.1.04
Conforms to FCC Rules, Part A, Class A |
- ± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for reflective incidents: ±1 m from 1 m to 1.5 km.
- ± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for non-reflective incidents: ±2 m for lengths £15 m, otherwise ±1 m.
- Finds and gives the location of an incident that has a reflectance larger than -55 dB. Detects incidents >1m after the bulkhead connector when the bulkhead reflectance is <35 dB. Detects incidents >3 m after an incident when the incident reflectance is <35 dB.
- With a backscatter coefficient of -63 dB at 850 nm using a calibrated -14 dB reference.
- Detects incidents >10 m after the bulkhead connector or any prior incident when the bulkhead reflectance is <-35 dB and the reflectance of any prior incident is <-35 dB. The maximum link loss prior to the incident is <7 dB.
|