General Specifications |
Speed of Autotest |
Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds; Full 2-way Autotest of Category 6A/Class
EA: 22 seconds |
Supported test parameters (test standard determines parameters and frequency range reported) |
Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), Near End Crosstalk (NEXT), Attenuation-to-Crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (PS ELFEXT), Power Sum NEXT, Power Sum ACR-N |
Maximum frequency |
500 MHz |
Test Result Storage |
250 with graphical data; >1500 without graphical data |
Display |
3.7 in (9.4 cm) diagonal, 240x320 pixel, passive color LCD with backlight |
Dimensions |
Main and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6 cm), nominal |
Weight |
2.4 lb (1.1 kg), nominal (without adapter or module) |
Battery |
Lithium-ion, 7.4 V, 4000 mAh |
Battery Life |
12 hours, typical |
Battery Charge Time |
4 hours (below 40˚ C, with tester off) |
Environmental Specifications |
Operating temperature |
32° F to 113° F (0° C to 45° C) |
Storage temperature |
-4° F to +140° F (-20° C to +60° C) |
Operating relative humidity (% RH without condensation) |
32° |
Vibration |
Random, 2 g, 5 Hz -500 Hz |
Shock |
1 m drop test with and without module and adapter attached |
Safety |
IEC 61010-1: Measurement Category None, Pollution Degree 2 |
Altitude |
Operating: 4000 m (3048 m with AC Adapter); Storage: 12000 m |
EMC |
EN 61326-1: Portable |