Model DSX2-CFP-Q-ADD-R Specifications |
Cable Types |
Shielded and unshielded pair LAN cabling |
TIA Cat 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA, and I/II: 100 Ω and 120 Ω |
Standard Link Interface Adapters |
Permanent link adapters |
Plug type: shielded RJ45
Optional Plug type: Tera |
Channel adapters |
Jack type: shielded RJ45
Optional Jack type: Tera, GG45 |
Test Standards |
TIA |
Cat 3, 4, 5, 5e, 6, 6A, 8 per TIA 568.2-D |
ISO/IEC |
Class C, D, E, EA, F, FA, I/II certification per ISO/IEC |
Maximum frequency |
DSX-8000: 2000 MHz
DSX-5000 1000 MHz |
General Specifications |
Speed of Autotest |
DSX-8000: Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds Full 2-way Autotest of Cat 6A/Class EA: 8 seconds Full 2- way Autotest of Cat 8: 16 seconds
DSX-5000: Full 2-way Autotest of Cat 5e or 6/Class D or E: 9 seconds Full 2-way Autotest of Cat 6A/Class EA: 10 seconds |
Support test parameters (The selected test standard determines the test parameters and the frequency range of the tests) |
Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Pair-to-Pair Resistance Unbalance, Pair Resistance Unbalance, Insertion Loss (Attenuation), Return Loss (RL), Common Mode Return loss (CMRL), Near-End Crosstalk (NEXT), Far End Crosstalk (FEXT), Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien NEXT (PS ANEXT), Power Sum Alien Attenuation NEXT Ratio Far End (PS AACR-F), Common Mode to Differential Mode NEXT (CDNEXT), Transverse Conversion Loss (TCL), Equal Level Transverse Conversion Transfer Loss (ELTCTL). |
Input protection |
Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
Display |
5.7 in LCD display with a projected capacitance touchscreen |
Case |
High impact plastic with show absorbing over mold |
Dimensions |
Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
Weight |
Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
Main unit and remote |
Lithium-ion battery pack, 7.2 V |
Typical battery life |
8 hours |
Charge time* |
Tester off: 4 hours to charge from 10 % capacity to 90 % capacity |
Languages supported |
English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian |
Calibration |
Service center calibration period is 1 year |
Integrated Wi-Fi |
Meets IEEE 802.11 a/b/g/n; dual-band (2.4 GHz and 5 GHz) |
Environmental Specifications |
Operating Temperature |
32° F to 113° F (0° C to 45° C) |
Storage Temperature |
-22° F to +140° F (-30° C to +60° C) |
Operating relative humidity (% RH without condensation) |
0% to 90%, 32° F to 95° F (0° C to 35° C)
0% to 70%, 95° F to 113° F (35° C to 45 °C) |
Vibration |
Random, 2 g, 5 Hz-500 Hz |
Shock |
1 m drop test with and without module and adapter |
Safety |
CSA 22.2 No. 61010, IEC 61010-1 3rd Edition |
Operating altitude |
13,123 ft (4,000 m)
10,500 ft (3,200 m) with ac adapter |
EMC |
EN 61326-1 |