General |
Display |
LVD (5 inches diagonal) |
Backlight |
Blue (adjustable duration) |
Over Range Display |
OL for pressure, ----for temperature |
Auto Power Off |
30 minutes of inactivity (adjustable) |
Maximum Manifold Pressure |
800 Psig (5500 kPa) |
Battery Type |
6x AA Alkaline |
Battery Life |
350 hours typical (without vacuum, backlight, and wireless) |
Radio Frequency |
2.4 GHz |
Wireless Range |
350 feet (106 meters) line of sight
Distance decreases through obstructions |
Data Port |
Micro USB (for extracting logged data or updating firmware) |
Operating Environment |
32°F to 122°F (0°C to 50°C) at <75% RH |
Storage Environment |
-4°F to 140°F (-20°C to 60°C) at <80% RH (with battery removed) |
Temperature Coefficient |
0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C), per 1.8°F (32°F to 64°F, 82°F to 122°F) |
Weight |
4.03 lbs (1.83 kg) |
Water Resistant |
Designed to IP54 |
US Patent |
www.fieldpiece.com/patents |
Refrigerants |
New refrigerants are continually being added so be sure to visit www.fieldpiece.com for the latest firmware |
Pressure |
Sensor Type |
Absolute pressure sensors |
Port Type |
(3) 1/4" standard NPT male flare fittings (SM380V)
(1) 3/8" and (3) 1/4" standard NPT male flare fittings (SM480V) |
Pressure Range and Units |
580 Psig (English), 40.00 Bar (Metric), 4,000 MPa (Metric), and 4000 kPa (Metric) |
Negative Pressure Range Units |
29 inHg (English), 74 cmHg (Metric) |
Resolution |
0.1 Psig; 0.01 Bar; 0.001 MPa; 1 kPa; 0.1 inHg; 1 cmHg |
Negative Pressure Accuracy |
29 inHg to 0 inHg: ±0.2 inHg; 75 cmHg to 0 cmHg: ±1 cmHg |
Pressure Accuracy |
0 Psig to 200 Psig: ±1 Psig; 200 Psig to 580 Psig: ±(0.3% of readings + 1 Psig); 0 Bar to 13.78 Bar: ±0.07 Bar; 13.78 Bar to 40.00 Bar: ±(0.3% of readings + 0.07 Bar); 0 MPa to 1.378 MPa: ±0.007 MPa; 1.378 MPa to 4.000 MPa: ±(0.3% of readings + 0.007 MPa); 0 kPa to 1378 Kpa: ±7 kPa; 1378 kPa to 4000 kPa: ±(0.3% of readings + 7 kPa) |
Temperature |
Sensor Type |
Type K thermocouple (nickel chromium/nickel aluminum) |
Jack Type |
(3) Type K thermocouple |
Range |
-50°F to 257°F (-46°C to 125°C), limited by thermocouple specification. Display range is -95°F to 999.9°F (-70°C to 537.0°C) |
Resolution |
0.1°F (0.1°C) |
Accuracy |
*Shown accuracies are after field calibration
±(1.0°F) -95°F to 200°F, ±(2.0°F) 200°F to 999.9°F; ±(0.5°C) -70°C to 93°C, ±(1.0°C) 93°C to 537.0°C |
Deep Vacuum |
Sensor Type |
Thermistor |
Port Type |
(3) 1/4" standard NPT male flare fittings (SM380V)
(1) 3/8" and (3) 1/4" standard NPT male flare fittings (SM480V) |
Range and Units |
50 to 9999 microns of mercury (English)
6 to 1330 pascals (Metric)
0.06 to 13.3 mBar (Metric)
50 to 9999 mTorr (Metric)
0.05 to 10 Torr (Metric, equivalent to mmHg) |
Best Resolution |
1 micron of mercury (below 2000 microns)
1 Pascal (below 250 Pascals)
0.001 mBar (below 2.5 mBar)
1 mTorr (below 2000 mTorr)
0.001 Torr (below 2.5 Torr) |
Accuracy @ 77°F (25°C) |
±(5% of reading + 5 microns of mercury)
±(5% of reading + 1 Pascal)
±(5% of reading + 0.01 mBar)
±(5% of reading + 5 mTorr)
±(5% of reading + 0.005 Torr) |
Wireless Compatibility |
Latest compatibility at www.fieldpiece.com |
Job Link System Minimum Device Requirement |
BLE 4.0 devices running iOs 7.1 or Android Kitkat 4.4 |
Wireless Measurement Source Assignments |
Suction line temperature: Fieldpiece model JL3PC (set to blue)
Liquid line temperature: Fieldpiece model JL3PC (set to red)
Supply air psychrometer: Fieldpiece model JL3RH (set to blue)
Return air psychrometer: Fieldpiece model JL3RH (set to red)
Refrigerant weight scale: Fieldpiece model SRS3, SRS3P |