Input Limits |
V DC, VAC | 600V DC/AC |
Ohms, Capacitance, Diode, Frequency, Continuity | 250V DC/AC |
mA DC/AC | 400mA DC/AC |
10A DC/AC | 10A DC/AC (30sec. max) |
General |
Diode Test | Test current of 0.3mA maximum, open circuit voltage 1.5V DC typical |
Continuity Check | Audible signal will sound if the resistance is less than approximately 30 Ω, test current <0.7mA |
Temperature sensor | Requires type K thermocouple |
Input Impedance | 7.5M Ω (VDC and VAC) |
Display | 4000 count LCD |
Overrange indication | “OL” is displayed |
Polarity | Automatic (no indication for positive polarity); Minus (-) sign for negative polarity. |
Measurement Rate | 2 times per second, nominal |
Auto Power Off | Meter automatically shuts down after 15 minutes of inactivity |
Low Battery Indication | “BAT” is displayed if battery voltage drops below operating voltage |
Batteries | Requires two AAA batteries |
Fuses | mA, μA ranges, 0.5A/250V fast blow 10A range, 10A/250V fast blow |
Operating Temperature | 32°F to 122°F (0°C to 50°C) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
Relative Humidity | <70% operating, <80% storage |
Operating Altitude | 7000ft (2000 meters) maximum. |
Weight | 9.17 oz. (260g). |
Size | 4.78” x 2.38” x 1.57” (121.5mm x 60.6mm x 40mm) |
Safety | For indoor use and in accordance with Overvoltage Category II, Pollution Degree 2. Category II includes local level, appliance, portable equipment, etc., with transient overvoltages less than Overvoltage Category III. |