General Specifications |
Display | Dual 7-segment 4-digit LED Displays: Red (PV), Green (SV) |
Status Indicators | For Control output, Alarm output, Over range, Auto-Tune, and Open Input |
LED display span | -1999 to 9999 counts max (Programmable) |
Indicating Accuracy | +0.2% Full Scale +1 digit |
Sampling Time | 1 reading per 0.25 seconds |
Memory | Nonvolatile type |
Meter Enclosure | ABS Plastic |
Front Panel | Lexan (Drip and Dust Proof; IEC IP55, NEMA Equivalent) |
Power Supply | 85 to 260VAC 50/60 Hz (automatic switching) |
Power Consumption | 6 Watts |
Insulation Resistance | >50M Ω |
Noise Rejection | Common Mode - 110 db typical, Normal Mode - 50 db typical |
Operating Temperature / Humidity | 14 to 122 °, F (-10 to 50 ° C), 90% RH max. |
Storage Temperature | -4 to 140 ° F (-20 to 60 ° C) |
Dimensions (Cutout) | 1.77 x 1.77" ±0.02" (45.0 x 45.0mm ±0.5mm) |
Input Specifications |
Thermocouple input | (Programmable) |
Types | J, K, T, E, B, R, S, N; Cold Junction Compensation |
Thermocouple Break Protection | Upscale and Downscale |
Lead Wire Effect | 0.015%/ohm (Input impedance: 10 megohm) |
RTD input | Pt 100 ohm (DIN, JIS) |
RTD Break Protection | Upscale and Downscale |
Lead Wire Effect | 0.015/ohm (automatically compensates if one lead wire is < 5 Ω ) |
Current input | 4-20mA DC (2.7 Ω input impedance) |
Voltage input | 1-5V DC |
Thermocouple Ranges |
Type K | -58 to 2498 ° F (-50 to 1370 ° C) |
Type J | -58 to 1830 ° F (-50 to 1000 ° C) |
Type B | 32 to 3272 ° F (0 to 1800 ° C) |
Type T | -454 to 752 ° F (-270 to 400 ° C) |
Type E | -58 to 1382 ° F (-50 to 750 ° C) |
Type R | 32 to 3182 ° F (0 to 1750 °o C) |
Type S | 32 to 3182 ° F (0 to 1750 ° C) |
Type N | -58 to 2372 ° F (-50 to 1300 ° C) |
RTD | PT100 input ranges -392 to 932 ° F (-200 to 500 ° C); (DIN or JIS) |
Linear input range | -1999 to 9999 display span (for 4-20mA, 1-5V, or special DC input). |
Temperature Stability | 5uV/° C typical |
Repeatability | 0.83 ° C (Thermocouple), 0.2 ° C (RTD), 1 digit (Linear) |
Output Specifications |
Control Output Relay | 5 Amps at 110V AC, SPDT (Resistive Load) |
Control Output DC Voltage | (Pulsed) 24V DC (DC drive for SSR) |
ON | 24V DC typical, 29V DC max. |
OFF | 0.3V DC max |
Analog Control Output | (Current) 4-20mA DC; Load limit: 600 O max. |
Alarm/Timer Types | High/Low Deviation/Absolute Alarms w/deadband adjust plus Soak/Event Timers |
Alarm Output Relay | 3 Amps at 110VAC, SPST (Resistive Load) |
Output Control Modes |
Proportional Band | 0.0 to 100.0% of Full Scale (can be Auto Tuned) |
Integral Time | 0 to 3000 secs. (can be Auto Tuned) |
Derivative Time | 0 to 3000 secs. (can be Auto Tuned) |
Cycle Time | 1 to 100 secs. (0 sec for 4-20mA output) |
Anti-Reset | Wind-Up Inhibits integral action outside of the Prop. Band |
Manual Reset | 0 to 100% of Prop. Band |
Hysteresis | 0.0 to 25.5% of Full Scale |