Basic Accuracy (DCV) |
0.5% |
0.5% |
0.5% |
NCV Detector |
80 to 1000V (50-60Hz) and
160 to 1000V (50-60Hz) |
80 to 1000V (50-60Hz) and
160 to 1000V (50-60Hz) |
80 to 1000V (50-60Hz) and
160 to 1000V (50-60Hz) |
DC/AC Voltage |
0.1mV to 1000V |
0.1mV to 1000V |
0.1mV to 1000V |
DC/AC Current |
— |
— |
1mA to 10A |
DC/AC µA Current |
— |
600µA |
— |
Resistance |
0.1Ω to 40MΩ |
0.1Ω to 40MΩ |
0.1Ω to 40MΩ |
Capacitance |
1nF to 10mF |
1nF to 10mF |
1nF to 10mF |
Frequency |
0.01Hz to 100kHz |
0.01Hz to 100kHz |
0.01Hz to 100kHz |
Temperature (Type K) |
— |
-40 to 742°F (-40 to 394°C) |
— |
Diode Test |
1.5V |
1.5V |
1.5V |
Continuity |
Audible and Visual |
Audible and Visual |
Audible and Visual |
Dimensions |
6.5x3.2x1.7" (164x82X44mm) |
6.5x3.2x1.7" (164x82X44mm) |
6.5x3.2x1.7" (164x82X44mm) |
Weight |
5.9oz (450g) |
5.9oz (450g) |
5.9oz (450g) |
Accuracy is given as ± (% of reading + least significant digit) at 23 °C ±5 °C with relative humidity
lower than 80%. Accuracy is specified for a period of one year after calibration.
1. Temperature Coefficient is 0.1 x specified accuracy / °C, < 18 °C (64.5 °F), > 28 °C (82.4 °F)
2. AC Functionality: ACV and ACA specifications are AC coupled, True RMS; the accuracy for
square waveforms is unspecified. For non-sinusoidal waveforms, additional accuracy Crest
Factor (C.F.) considerations exist as detailed below:
Add 3.0% for C.F. 1.0~2.0; Add 5.0% for C.F. 2.0~2.5; Add 7.0% for C.F. 2.5~3.0 |
Function |
Range |
Resolution |
Accuracy (of reading) |
‘OL’ Reading |
mV DC |
600.0mV |
0.1mV |
± (0.5% + 5 digits) |
660.0mV |
Input Impedance: 10M; Overload Protection: AC/DC 1000V |
DC Voltage |
6.000V |
0.001V |
± (0.5% + 2 digits) |
6.600V |
60.00V |
0.01V |
66.00V |
600.0V |
0.1V |
660.0V |
1000V |
1V |
1100V |
Input Impedance: 10M; Overload Protection: AC/DC 1000V |
AC Voltage |
600.0mV |
0.1mV |
± (1.0% + 5 digits) |
660.0mV |
6.000V |
0.001V |
± (1.0% + 3 digits) |
6.600V |
60.00V |
0.01V |
66.00V |
600.0V |
0.1V |
660.0V |
1000V |
1V |
1100V |
LCD Displays ‘0’ counts when the reading < 10 counts
Input Impedance: 10MΩ (< 100pF)
Frequency Response: 45~500Hz (sine wave)
Over load protection: 1000V AC/DC |
Lo Z (Low Impedance) |
600.0V |
0.1V |
± (2.0% + 3 digits) |
660.0V |
1000V |
1V |
1100V |
LCD Displays ‘0’ counts when the reading < 10 counts
Input Impedance: < 3kΩ
Frequency Response: 45~500Hz (sine wave); Over load protection: 1000V AC/DC |
µA DC (EX363 only) |
600.0 µA |
0.1uA |
± (1.0% + 2 digits) |
660.0µA |
Input Impedance: 3k approx.
Over load protection: 1000V AC/DC |
µA AC (EX363 only) |
600.0 µA |
0.1uA |
± (1.5% + 3 digits) |
660.0µA |
LCD Displays ‘0’ counts when the reading < 10 counts
Input Impedance: 3kΩ approx.
Frequency Response: 45~500Hz (sine wave)
Over load protection: 1000V AC/DC |
AC Current (EX365) |
6.000 A |
0.001 |
± (1.5% + 3 digits) |
6.600A |
10.00 A |
0.01 |
20.00A |
In 6A Range, the LCD displays 0 counts when the reading < 20 counts.
In10A Range, the LCD displays 0 counts when the reading < 10 counts.
Maximum measurement time: >5A for max. 3 minutes with at least 20 minutes rest time.
>10A for max. 30 seconds with at least 10 minutes rest time.
Frequency Response : 45 ~ 500Hz (Sine Wave)
Overload Protection : AC/DC 11A |
DC Current (EX365) |
6.000 A |
0.001 |
± (1.0% + 3 digits) |
6.600A |
10.00 A |
0.01 |
20.00A |
Maximum measurement time : >5A for max. 3 minutes with at least 20 minutes rest time.
>10A for max. 30 seconds with at least 10 minutes rest time.
Overload Protection : AC/DC 11A |
Resistance |
600.0 Ω |
0.1 Ω |
± (0.9% + 5 digits) |
660.0 Ω |
6.000k Ω |
0.001k Ω |
± (0.9% + 2 digits) |
6.600 kΩ |
60.00k Ω |
0.01k Ω |
± (0.9% + 2 digits) |
66.00 kΩ |
600.0k Ω |
0.1k Ω |
± (0.9% + 2 digits) |
660.0 kΩ |
6.000M Ω |
0.001M Ω |
± (0.9% + 2 digits) |
6.600 MΩ |
40.00M Ω |
0.01M Ω |
± (1.5% + 5 digits) |
44.00 MΩ |
Overload Protection: 1000V AC/DC
Note that digits may fluctuate ±50 digits when measuring above 10.00M |
Continuity |
600.0 Ω |
0.1 Ω |
± (0.9% + 5 digits) |
660.0 Ω |
Continuity: Built-in beeper sounds when measured resistance is less than 20O. Beeper turns off when
measured resistance goes above 200O
Continuity beeper frequency tone: 2KHz; Response Time: < 500µsec.; Overload Protection: AC/DC 1000V |
Diode |
1.550V |
0.001V |
± (0.9% + 2 digits) |
n/a |
Open Circuit Voltage : Approx. 1.8V; Overload Protection : AC/DC 1000V |
Capacitance |
1.000 µF |
0.001 µF |
± (1.9% + 5 digits) |
1.100 µF |
10.00 µF |
0.01 µF |
± (1.9% + 2 digits) |
11.00 µF |
100.0 µF |
0.1 µF |
110.0 µF |
1.000 mF |
0.001 mF |
1.100 mF |
10.00 mF |
0.01 mF |
11.00 mF |
Overload Protection: 1000V AC/DC |
Frequency |
100.00 Hz |
0.01 Hz |
± (0.1% + 2 digits) |
100.00 Hz |
1000.0 Hz |
0.1 Hz |
1000.0 Hz |
10.000 kHz |
0.001kHz |
10.000 kHz |
100.00 kHz |
0.01kHz |
100.00 kHz |
Minimum Sensitivity: > 5V (for ACV 1Hz ~ 10kHz) > 20.0V (for ACV 10kHz ~ 50kHz)
unspecified (for ACV 50kHz ~ 100kHz) >0.6A (for ACA)
Minimum Frequency: 1Hz
Overload Protection: AC/DC 1000V or 11A |
Temp. (EX363) |
-40.0~400.0 °C |
0.1° |
± (1.0% + 20 digits)* |
440.0 °C |
-40.0~752.0 °F |
0.1° |
± (1.0% + 36 digits)* |
824.0 °F |
*Does not include accuracy of the temperature probe. Accuracy specifications
assume surrounding temperature stable to ±1 o C. For ambient temperature
changes of ±2 o C, rated accuracy applies after 2 hours of stabilization time.
OVERLOAD PROTECTION: AC/DC 1000V |
Peak MIN-MAX |
|
Specified accuracy
± 150 digits |
|
Accuracy of square wave is unspecified |
Non-Contact
Voltage Detector |
80~1000V (high sensitivity mode) 50~60Hz |
160~1000V (low sensitivity mode) 50~60Hz |
The tip of the meter offers the optimum sensitivity |