Output Voltage |
1 to 60V |
Output Current |
1 to 10A |
Basic Accuracy |
±(0.2%+3 digits) |
Load Voltage Regulation |
50mV |
Line Voltage Regulation |
20mV |
Load Current Regulation |
100mA |
Line Current regulation |
50mA |
Ripple and Noise |
≤5m Vrms, ≤100m Vp-p |
Dimensions/ Weight |
7.9 x 3.5 x 8.5” (200 x 90 x 215mm)/ 5.7lbs (2.6kgs) |
Output |
Variable Voltage Output |
1 to 60VDC |
Variable Current Output |
0 to 10ADC |
Voltage Regulation |
Load (10 to 100% Load) |
50mV |
Model DCP60 |
Line (90 to 130VAC Variation) |
20mV |
Model DCP60-220 |
Line (170 to 264VAC Variation) |
20mV |
Current Regulation |
Load (10 to 90% rated voltage) |
100mA |
Model DCP60 |
Line (90 to 130VAC Variation) |
50mA |
Model DCP60‐220 |
Line (170 to 264VAC Variation |
50mA |
Ripple and Noise |
Ripple and Noise (RMS) voltage |
5mV |
Ripple and Noise (P-P) voltage |
100mv |
Current Ripple and Noise (RMS) |
10mA |
Meter Type and Accuracy |
Voltage Meter |
3-digit LED Display ±0.2% + 3 counts |
Current Meter |
3-digit LED Display ±0.2% + 3 counts |
Input |
Input Voltage |
Model DCP60: 90 to 130VAC 50/60Hz
Model DCP60-220: 220 to 240CVAC 50/60Hz |
Fuse |
8A/250V 5x20mm (120V); 4A/250V 5x20mm (220V) |
Full Load Current |
6.2A (120V); 3.25A (220V) |
Installation category |
CAT 2 |
Other |
Efficiency |
89% |
Switching Frequency |
65 to 85 kHz (approx.) |
Tracking Over-Voltage Protections |
O/P 1‐5V: set voltage +2V
O/P 5‐20V: set voltage +3V
O/P 20‐60V: set voltage +4V |
Transient Response Time (50-100% load) |
1.5ms |
Power Factor Control |
Power Factor correction >0.9 at optimal load |
Cooling method |
Thermostatic control fan from zero to full speed |
Protections |
Overload, Short Circuit by Constant Current, Output
Tracking Over Voltage, and Over Temperature |
Operating %RH |
10 to 80% Relative Humidity |
Approvals |
CE, EMC: EN 55011, 55022, LVD: EN 60950, 61010 |
Dimensions |
7.9 x 3.5 x 8.5" (200 x 90 x 215mm) |
Weight |
5.7lbs. (2.6 kg) |
Altitude |
up to 6561 ft. (2000m) |
Pollution degree |
2 |