| Inputs |
Type K |
-58 to 2498°F (-50 to 1370°C) |
| Type J |
-58 to 1832°F (-50 to 1000°C) |
| Type B |
-32 to 3272°F ( 0 to 1800°C) |
| Type T |
-454 to 752°F (-270 to 400°C) |
| Type E |
-58 to 1382°F (-50 to 750°C) |
| Type N |
-58 to 2372°F (-50 to 1300°C) |
| Type C |
-58 to 3272°F (-50 to 1800°C) |
| PT100&937; RTD (DIN) |
-328 to 1652°F (-200 to 850°C) |
| PT100&937; RTD (JIS) |
-328 to 1202°F (-200 to 650°C) |
| Control/Alarm Relay |
5 Amp @ 110V, SPST (resistive load) |
| DC Current Output |
4-20mA (resistive); Impedance < 600 ohms |
| Accuracy |
Thermocouple: ±1.8°F (1ºC); RTD: ±0.36°F (0.2ºC) |
| Sampling Time |
Four (4) samples per second |
| LED Display |
Two 4-digit displays for
Process Value, Setpoint, and programming modes |
| LED Status |
Alarm and Control output status |
| Control Modes |
Fuzzy Logic enhanced three-term PID with Auto Tune |
| Proportional Band 0 to 300.0% |
| Integral time 0 to 3600 seconds |
| Derivative time 0 to 900 seconds |
| Hysteresis 0.0 to 200.0 or 0.0 to 2000 |
| Cycle time 1 to 100 seconds |
| Front Panel |
Lexan construction, Drip/Dust proof; IR rating: IEC IP63 |
| Power Supply |
90 to 264 VAC; 50/60 Hz (< 5VA power consumption) |