Model: EA-PS 3200-10 C Specifications |
Product Type |
DC Laboratory Power Supply |
Housing |
Desktop (table) |
Voltage (U) |
200.00 |
Current (I) Ampere |
10.00 |
Power (P) Watt |
640.00 |
Resistance (R) |
No |
Characteristic Curve |
U/I conventional |
Human Interface |
Simple manual controls |
Ext. control - analogue 0-5V/0-10V |
Yes |
External control - GPIB (IEEE488) |
No |
External control - USB |
Yes |
External control - RS232 |
No |
External control - CAN |
No |
External control - LAN |
Yes |
External control - Profibus |
No |
External control - DeviceNet |
No |
external control - Modbus TCP |
No |
Function generator |
No |
Special feature - High-Speed |
No |
Special feature - Sink |
No |
Special feature - water cooled |
No |
Specific Technical Details |
AC Input |
Voltage range |
90...264 V AC |
Connection |
Wall outlet |
Frequency |
45-65 Hz |
Fusing |
MT 4 A |
Leak current |
< 3.5 mA |
Power factor |
~ 0.99 |
DC Output |
Max. output voltage UMax |
200 V |
Max. output current IMax |
4 A |
Max. output power PMax |
640 W |
Overvoltage protection range |
0...220 V |
Overcurrent protection range |
0...11 A |
Overpower protection range |
0…704 W |
Output capacitance |
600 μF |
Temperature coefficient for set values Δ/K |
Voltage / current: 100 ppm |
Voltage regulation |
Adjustment range |
0...204 V |
Accuracy |
< 0.1% U Max |
Line regulation at ±10% ΔU AC |
< 0.02% U Max |
Load regulation at 0...100% load |
< 0.05% U Max |
Settling time after load step |
< 1.5 ms |
Display: Accuracy |
≤ 0.2% U Max |
Ripple |
< 100 mV PP
< 25 mV RMS |
Remote sensing compensation |
Max. 5% U Max |
Output voltage fall time (at no load) after switching DC output off |
Down from 100% to <60 V: less than 10 s |
Current regulation |
Adjustment range |
0...10.2 A |
Accuracy (1 (at 23 ± 5°C) |
< 0.2% I Max |
Line regulation at ±10% |
< 0.05% I Max |
Load regulation at 0...100% ΔU OUT |
< 0.15% I Max |
Ripple |
< 12 mA RM |
Display: Accuracy |
≤ 0.2% I Max |
Power regulation |
Adjustment range |
0…652.8 W |
Accuracy (1 (at 23 ± 5°C) |
< 1% P Max |
Line regulation at ±10% ΔU AC |
< 0.05% P Max |
Load reg. at 10-90% ΔU OUT*ΔI OUT |
< 0.75% P Max |
Power regulation |
Display: Accuracy |
≤ 0,5% P Nenn |
Analog interface (optional) |
Set value inputs |
U, I, P |
Actual value output |
U, I |
Control signals |
DC on/off, remote control on/off |
Status signals |
CV, OVP, OT |
Galvanic isolation to the device |
Max. 1500 V DC |
Sample rate of inputs & outputs |
Max. 100 Hz |
Insulation |
Output (DC) to enclosure (PE) |
DC minus: permanent max. ±400 V
DC plus: permanent max. ±400V + output voltage |
Input (AC) to output (DC) |
Max. 2500 V, short-term |
Miscellaneous |
Cooling |
Temperature controlled fan, side inlet, rear exhaust |
Ambient temperature |
0..50°C |
Storage temperature |
-20...70°C |
Humidity |
< 80%, not condensing |
Standards |
EN 61010, EN 60950 |
Overvoltage category |
2 |
Protection class |
1 |
Pollution degree |
2 |
Operational altitude |
< 2000 m |
Digital interfaces |
Optionally available |
IF-KE5 USB: 1x USB
IF-KE5 USBLAN: 1x USB + 1x LAN
IF-KE5 USBANALOG: 1x USB + 1x Analog
|
Galvanic isolation from device |
Max. 1500 V DC |
Terminals |
Rear side |
AC input, analog interface (optional), USB (optional), Ethernet (optional) |
Front side |
DC output, USB-A, remote sensing |
Dimensions |
Enclosure (WxHxD) |
260 x 88 x 323 mm |
Total (WxHxD) |
308 x min. 103 x min. 359 mm |
Weight |
~ 5 kg |
Article number |
35320216 |