INPUT |
340XAC |
Phase |
1Ø or 3Ø |
Voltage |
1Ø: 200 - 240 VAC ±10%
3Ø3W: 200 - 240 VAC ±10%
3Ø4W: 346 - 416 VAC ±10% |
Frequency |
47 - 63 Hz |
OUTPUT |
Voltage |
5 - 300 V |
Max Power |
6 kVA |
Max Current 1Ø |
0 - 150 V |
55.2 A @ ≤110 V |
0 - 300 V |
27.6 A @ ≤220 V |
Phase |
1Ø (Parallel/Poly-Phase Linking for 1Ø3W or 3Ø4W) |
Frequency |
40.0 - 1000 Hz |
THD |
<1% (Resistive Load) |
Crest Factor |
Inrush CF ≥3 at 110 V, Continuous Current CF ≥3 at 110 V |
Line Regulation |
± 0.1 V |
Load Regulation |
± 0.5 V |
DC OUTPUT VOLTAGE |
Voltage |
5 - 420 V |
Max Power |
6000 W |
Max Current 1Ø |
0 - 210 V |
28.8 A |
0 - 420 V |
14.4 A |
Ripple & Noise (Peak to Peak) |
<4.0 V |
MEASUREMENT |
Voltage |
Range |
0.0 - 400.0 V |
Accuracy |
± (1% of reading + 5 counts) >5 V |
Frequency |
Range |
0.0 - 1000 Hz |
Accuracy |
0.0 - 500 Hz ± 0.1 Hz, 501 - 1000 Hz ± 0.2 Hz |
Current (RMS) |
Range |
0.005 A - 78.00 A |
Accuracy |
± (1% of reading + 5 counts) @ 40 - 100 Hz, ± (1% of reading + 5 counts) @ 101 - 500 Hz >0.1 A, ± (1% of reading + 5 counts) @ 501 - 1000 Hz >0.2 A |
Current Peak |
Range |
0.0 A - 228 A |
Accuracy |
± (1% of reading + 5 counts) |
Power |
Range |
0.0 W - 7800 W |
Accuracy |
L |
± (2% of reading + 5 counts) at PF ≥0.2 |
H |
± (2% of reading + 5 counts) at PF ≥0.2 |
Power Apparent (VA) |
Range |
0.0 VA - 7800 VA |
Calculated Formula |
V×A, Calculated value |
Power Reactive (Q) |
Range |
0.0 VAR - 7800 VAR |
Calculated Formula |
√(VA)²-(W)², Calculated value |
Power Factor |
Range |
0.000 - 1.000 |
Calculated Formula |
W/VA, Calculated and displayed to three significant digits |
Crest Factor |
Range |
0.0 - 10.0 |
Accuracy |
A peak / Arms, Calculated and displayed to two significant digits |
OPTIONS |
Grounded Neutral |
Option 2 |
All Models |
GPIB Interface |
Option 3 |
All Models |
7 Remote Memory |
Option 4 |
All Models |
Ethernet Interface |
Option 6 |
All Models |
Linking Card |
Option 8 |
All Models |
GENERAL |
Operation Environment |
0 - 40ºC / 20 - 80% RH |
Dimensions (W x H x D |
16.92 x 15.77 x 19.69 in |
430 x 400.5 x 500 mm |
Net Weight |
117 lbs (53 kg) |
Linking Parallel Output 1Ø2W |
Linked Units |
2 - 3 Units, 1Ø2W (L1 - N) |
Voltage |
Phase |
5 - 300 V |
Power Max |
# Units |
2 |
10.8 kVA |
3 |
16.2 kVA |
Max Current |
0 - 150 V |
L(2) |
88.32 A @ 20 V -110 V |
L(3) |
132.48 A @ 20 V - 110 V |
Line (RMS) |
0 - 300 V |
H(2) |
44.16 A @ 20 V - 220 V |
H(3) |
66.24 A @ 20 V - 220 V |
Linking Polyphase Output 1Ø3W |
Linked Units |
2 Units @ 180º, 1Ø3W (L1-L2 - N) |
Voltage |
Phase |
10 - 600 V |
Line |
5 - 300 V |
Power |
Max |
12 kVA |
Max Current Phase |
0 - 300 V |
L(1) |
55.2 A @ ≤110 V |
0 - 600 V |
H(1) |
27.6 A @ ≤220 V |
Max Current Line |
0 - 300 V |
L(2) |
55.2 A @ ≤220 V |
0 - 600 V |
H(2) |
27. A @ ≤440 V |
Linking Polyphase Output 3Ø4W |
Linked Units |
3 Units @ 120º, 3Ø4W (L1-L2-L3 - N) |
Voltage |
Phase |
5 - 300 V |
Line |
5 - 520 V |
Power |
Max |
18 kVA |
Max Current Phase |
0 - 150 V |
L(1) |
55.2 A @ ≤110 V |
0 - 300 V |
H(1) |
27.6 A @ ≤220 V |
Max Current Line |
0 - 150 V |
L(3) |
55.2 A @ ≤190.5 V |
0 - 300 V |
H(3) |
27.6 A @ ≤381 V |
Max Current Phase Delta |
0 - 260 V |
L(3) |
31.87 A @ ≤190.5 V |
0 - 520 V |
H(3) |
15.93 A @ ≤381 V |
Linking Parallel DC Output 1Ø2W |
Linked Units |
2 - 3 Units, 1Ø2W (L1 - N ) |
Voltage Power |
Line |
5 - 420 V |
Power Max |
# Units |
2 |
10.8 kVA |
3 |
16.2 kVA |
Max Current |
0 - 210 V |
L(2) |
46.08 A @ 50 V - 210 V |
L(3) |
69.12 A @ 50 V - 210 V |
Line |
0 - 420 V |
H(2) |
23.04 A @ 50 V - 420 V |
H(3) |
34.56 A @ 50 V - 420 V |
Measurement (Total) Linking Parallel 1Ø2W |
Voltage |
Range |
0.0 - 400.0 V |
Accuracy |
± (1% of reading + 5 counts) >5 V |
Frequency |
Range |
0.0 - 1000.0 Hz |
Accuracy |
L |
± 0.1 Hz @ 0.0 - 500 Hz |
H |
± 0.2 Hz @ 501 - 1000 Hz |
Current (RMS) |
Range |
2 |
0.00 A - 156.0 A |
3 |
0.00 A - 234.0 A |
Accuracy |
L |
± (1.5% of reading +15 counts) x Link Units @ 40.0 - 70.0 Hz and Current (RMS) >3.00 A, ± (1.5% of reading +15 counts) x Link Units @ 70.1 - 1000 Hz, and Current (RMS) >15.00 A |
H |
± (1.5% of reading +15 counts) x Link Units @ 40.0 - 70.0 Hz and Current (RMS) >3.00 A, ± (1.5% of reading +15 counts) x Link Units @ 70.1 - 1000 Hz, and Current (RMS) >15.00 A |
Power (W) |
Range |
2 |
0 W - 15600 W |
3 |
0 W - 23400 W |
Accuracy |
± (2% of reading + 10 counts) x (# of Linked Units) at PF ≥0.2, 40 - 500 Hz, and Current >5.0 A
± (2% of reading + 10 counts) x (# of Linked Units) at PF ≥0.3, 501 - 1000 Hz, and Current >5.0 A |
Power Apparent (VA) |
Range |
2 |
0 W - 15600 VA |
3 |
0 W - 23400 VA |
Accuracy |
V x A, Calculated Value |
Power Reactive (Q) |
Range |
2 |
0 W - 15600 VA |
3 |
0 W - 23400 VA |
Accuracy |
√(VA)² - (W)², Calculated Value |
Power Factor |
Range |
0 - 1.000 |
Accuracy |
W / VA, Calculated and displayed to three significant digits |
Measurement (Total) Linking Polyphase 1Ø3W |
Voltage |
Range |
2 |
L1 Voltage + L2 Voltage |
Accuracy |
Summation of linked sources, Calculated and displayed to one significant digit |
Frequency |
Range |
0.0 - 1000.0 Hz |
Accuracy |
L |
± 0.1 Hz @ 0.0 - 500 Hz |
H |
± 0.2 Hz @ 501 - 1000 Hz |
Current (RMS) |
Range |
2 |
(L1 Current + L2 Current)/2 |
Accuracy |
± (1% of reading + 5 counts) at 40 - 70 Hz
± (1% of reading + 5 counts) at 70.1 - 500 Hz, and output current (RMS) >0.200 A
± (1% of reading + 5 counts) at 501 - 1000 Hz, and output current (RMS) >0.300 A |
Power (W) |
Range |
2 |
L1 Power + L2 Power |
Accuracy |
2 |
L1 Power + L2 Power, Calculated Value |
Power Apparent A) |
Range |
2 |
L1 VA + L2 VA |
Accuracy |
2 |
L1 VA + L2 VA, Calculated Value |
Power Reactive (Q) |
Range |
2 |
L1 VAR + L2 VAR |
Accuracy |
2 |
L1 VAR + L2 VAR, Calculated Value |
Power Factor |
Range |
0 - 1.000 |
Accuracy |
(L1 P + L2 P) / (L1 VA + L2 VA), Calculated and displayed to three significant digits |
Measurement (Total) Linking Polyphase 3Ø4W |
Voltage |
Range |
(A+B+C)/3 |
Accuracy |
(A+B+C)/3, Calculated and displayed to one significant digit |
Frequency |
Range |
0.0 - 1000.0 Hz |
Accuracy |
L |
± 0.1 Hz @ 0.0 - 500 Hz |
H |
± 0.2 Hz @ 501 - 1000 Hz |
Current (RMS) |
Range |
(A+B+C)/3 |
Accuracy |
± (1% of reading + 5 counts) at 40 - 70 Hz
± (1% of reading + 5 counts) at 70.1 - 500 Hz, and output current (RMS) >0.200 A
± (1% of reading + 5 counts) at 501 - 1000 Hz, and output current (RMS) >0.300 A |
Power (W) |
Range |
A Power + B Power + C Power |
Accuracy |
Calculated Value |
Power Apparent (VA) |
Range |
A VA + B VA + C VA |
Accuracy |
Calculated Value |
Power Reactive (Q) |
Range |
A VAR + B VAR + C VAR |
Accuracy |
Calculated Value |
Power Factor |
Range |
0 - 1.000 |
Accuracy |
Sum P / Sum VA, Calculated and displayed to three significant digits |
Measurement (Total) Linking Parallel DC |
Voltage |
Range |
0.0 - 420.0 V |
Accuracy |
± (1% of reading + 2 counts) >5 V |
Current (RMS) |
Range |
2 |
0.05 A - 156.00 A |
3 |
0.05 A - 234.00 A |
Accuracy |
± (1% of reading + 5 counts) x # of Linked Units, Current >3.00 A |
Power (W) |
Range |
2 |
0 W - 15600 W |
3 |
0 W - 23400 W |
Accuracy |