GE Druck Pace 6000 General Specifications |
Standard Pressure Ranges |
350 and 700 mbar gauge, 1, 2, 3.5, 7, 10, 20, 35, 70, 100, 135, 172 and 210 bar gauge
5, 10, 15, 30, 50, 100, 150, 300, 500, 1000, 1500, 2000, 2500, 3000 psi
35, 70, 100, 200, 350, 700 kPa, 1, 2, 3.5, 7, 10, 13.5, 17.2, 21 MPa
All gauge versions available with negative calibration as standard. For absolute pressure ranges select any gauge range of 1 bar and above and add barometric option |
Over Range Indication |
10% above mbar/bar full scale pressure range |
Pressure Media |
Dry, oil free, non-corrosive gas maintained at a value of 10% above the maximum required output pressure. Dry air or Nitrogen recommended. |
For low pressure ranges below 350 mbar please consult your sales representative. |
Panel |
7” (17.5 cm) TFT colour VGA resolution wide format display with integral touchscreen. |
Comms Update Rate |
8 times per second |
Display Update Rate |
2 times per second |
Readout |
± 9999999 |
Pressure Units |
mbar, bar, Pa(N/m 2 ), hPa, kPa, MPa, mmHg @ 0°C, cmHg @ 0°C, mHg @ 0°C,, inHg @ 0°C, mmH 2 O @ 4°C, cmH 2 O @ 4°C, mH 2 O @ 4°C, mmH 2 O @ 20°C, cmH 2 O @20 °C, mH 2 O @ 20 °C, kg/m 2 , kg/cm 2 , torr, atm, psi, lb/ft 2 , inH 2 O @ 4°C, inH 2 O@ 20°C, inH 2 O @ 60°C, ftH 2 O @ 4°C, ftH 2 O @ 20°C, ftH 2 O @ 60°C, User Defined 1, User Defined 2, User Defined 3, User Defin |
Gauge Mode Precision |
0.005% Rdg + 0.005% FS includes linearity, hysteresis, repeatability and temperature effects for gauge pressures and assumes steady state temperature and regular zeroing. |
Negative Gauge Precision |
Maximum error at any given pressure value is equal to maximum error at the equivalent positive pressure value. |
Absolute Mode Precision |
Gauge mode precision + barometric reference precision |
Barometric Reference Precision |
Optional barometric reference 0.05 mbar or 0.000725 psi. Includes non-linearity, hysteresis, repeatability and temperature effects between 15°C (59°F) and 45°C (113°F) |
Controller Stability |
0.001% FS |
Long term stability |
To 0.01% reading per annum. 2 bar to 210 bar. 0.02% Rdg, 1bar & 0.03% Rdg, 350 mbar - 700 mbar. Barometer 0.1 mbar/ annum |
Gas Consumption |
All supply gas is delivered to the system. No gas is used in measure mode, or when the instrument is turned off |
Altitude range -3000 to +55,000 ft (Altitude precision based on 35 to 1150 mbar range ) |
Sea level |
±2 ft |
8500 ft |
±3 ft |
35,000 ft |
±9 ft |
Airspeed range to 650 knots (Airspeed precision based on 1000 mbar g range) |
50 knots |
±1.00 kts |
250 knots |
±0.21 kts |
500 knots |
±0.11 kts |
(Specifications assume steady state and regular zeroing.) |
Power Supply |
90 V AC to 130 V AC @ 47 to 63 Hz & 180 V AC to 260 V AC @ 47 to 63 Hz. [Universal input.] |
Communication |
RS232, IEEE-488, SCPI, DPI515, DPI510 and DPI500 emulation. Future expandability. |
Temperature |
Operating |
10°C to 50°C (50°F to 122°F) |
Calibrated |
15°C to 45°C (59°F to 113°F) |
Storage |
-20°C to 70°C (-4°F to 158°F) |
Sealing |
IP20 |
Humidity |
5% RH to 95% RH non-condensing. |
Vibration |
Compliant with Def. Stan. 66-31 8.4 Cat 3 and MIL-T-28800E Cat 2. |
Shock |
Mechanical shock conforms to EN61010. |
Conformity |
LVD EN61010, EMC EN61326, PED, ROHS & WEEE - CE marked. |
Weight |
12.5 kg or 27.5 lbs with single control module 17.5 kg or 38.5 lbs with dual control module |
Dimensions |
440 mm x 3U x 320 mm (17.3 in x 3U x 12.6 in) |
Pneumatic Connections |
G ⅛ female |
Optional: G ⅛ male to ⅛ NPT female adaptor*, G ⅛ male to 7/16 – 20 UNF female adaptor, G ⅛ male to ¼ NPT female adaptor*, G ⅛ male to AN4 37 Deg male adaptor, G ⅛ male to G ¼ female adaptor, G ⅛ male to AN6 37 Deg male adaptor, G⅛ male to ¼ I.D. hose adaptor. IO-ADAPTOR-KIT-contains one of each of the above adaptors. |
*Required by US customers (5 for each control module)
Differential connection kit Low Pressure
Snubber reference port
Diffuser gas exhaust
Rack mount kit PACE6000
Negative gauge generator
Vacuum system assembly |
Leak Test |
Test Program |
Switch Test [with electrical connector] |
Analog O/P |
Volt Free contacts |
Burst Test |
Aeronautical |
UKAS calibration PACE6000 (per module) |