Full-Time Continuous Monitor, 120VAC
The Desco 19325 Full Time Continuous Monitor provides 100% monitoring of both the operator and the work surface. This unit provides continuous monitoring of one user wearing a wrist strap, ESD worksurface, ground, and AC outlet.
Note: The worksurface must have a conductive layer such as Dual Layer Rubber, Dissipative 3-Layer Vinyl, or Micastat Dissipative Laminate with conductive buried layers. Desco Continuous Monitors are not recommended for use with homogeneous matting.
If the unit detects that the elements are outside industry standards, the continuous monitor will alarm with both an audible alarm and an illuminated red LED to notify the user of a problem. Unlike many units, the Full Time Continuous Monitor also continuously verifies ground (AC outlet ground). When the Power Cord is plugged in, a self-test runs automatically. If the AC outlet is wired incorrectly, both red LEDs will illuminate and the audible alarm will sound. The unit has an additional ground point for a user or supervisor.