Accuracy | TEMPERATURE SENSOR: ±0.4 °C
HUMIDITY SENSOR: ± 1.8 % RH
DEW POINT: ±1.5 °C at ambient temperature T <25 °C and RH >30 %
ATMOSPHERIC PRESSURE SENSOR: ±1.3 hPa at 23 °C from 800 to 1100 hPa | ±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C | ±0.2°C; ±0,2 % of the measurement value in a range
of +100 to +260 °C | TEMPERATURE SENSOR: ±0.4 °C
TEMPERATURE SENSOR - EXTERNAL PROBE PT1000: ±0.2 °C (-50 to +100 °C); ±0.2 % from reading from +100 to +260 °C; ±0.4 % from reading from -90 to -50 °C
| ±0.4 °C | ±0.4 °C | ±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C | ±0.2°C; ±0.2 % of the measurement value in a range of +100 to +260 °C | ±0.2°C; ±0.2 % from reading from +100 to +260 °C | ±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C | ±1.5 °C at ambient temperature T <25 °C and RH >30% | ±1.5 °C at ambient temperature T <25 °C and RH >30% | | | TEMPERATURE SENSOR: ±0.4 °C
HUMIDITY SENSOR: ± 1.8 % RH
DEW POINT: ±1.5 °C at ambient temperature T <25 °C and RH >30 %
CO2 SENSOR: ±(50ppm +3% from reading) at 25°C and 1013hPa | TEMPERATURE SENSOR: ±0.4 °C
TEMPERATURE SENSOR - EXTERNAL PROBE PT1000: ±0.2 °C (-50 to +100 °C);
±0.2 % from reading from +100 to +260 °C;
±0.4 % from reading from -90 to -50 °C
HUMIDITY SENSOR: ± 1.8 % RH
DEW POINT: ±1.5 °C at ambient temperature T <25 °C and RH >30 % | TEMPERATURE SENSOR: ±0.4 °C
HUMIDITY SENSOR: ± 1.8 % RH
DEW POINT: ±1.5 °C at ambient temperature T <25 °C and RH >30 % | ±1.5 °C at ambient temperature T <25 °C and RH >30% | ±1.5 °C at ambient temperature T <25 °C and RH >30% | ±10 mV | ±20 µA | Accuracy ±20 µA | | | ±(50ppm +3% from reading) at 25°C and 1013hPa | ±0.4 °C | ±0.2°C; ±0.2 % of the measurement value in a range of +100 to +260 °C | ±0.2°C; ±0.2 % of the measurement value in a range of +100 to +260 °C | ±0.2°C; ±0.2 % of the measurement value in a range of +100 to +260 °C | ±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C | Temperature measurement accuracy: ±0.4 °C
Humidity measurement accuracy: ± 1.8 % RH
Dew point measurement accuracy: ±1.5 °C at ambient temperature T <25 °C and RH >30 % | Temperature/Humidity/Dew Point measurement and accuracy: according to the connected probe Digi/E | Temperature measurement accuracy:
±0.2 °C (-50 to +100 °C);
±0.2 % from reading from +100 to +260 °C;
±0.4 % from reading from -90 to -50 °C
Humidity measurement accuracy: ± 1.8 % RH
Dew point measurement accuracy: ±1.5 °C at ambient temperature T <25 °C and RH >30 % | Temperature measurement accuracy: ±0.4 °C
Humidity measurement accuracy: ± 1.8 % RH
Dew point measurement accuracy: ±1.5 °C at ambient temperature T <25 °C and RH >30 %
CO2 measurement accuracy: ±(50ppm +3% from reading) at 25°C and 1013hPa
Atmospheric pressure measurement accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa | | ±10 mV | Voltage measurement accuracy: ±20 µA | Current measurement accuracy: ±20 µA | | | | ±0.2°C; ±0,2 % of the measurement value in a range
of +100 to +260 °C | ±0.2°C; ±0,2 % of the measurement value in a range
of +100 to +260 °C |
---|