Specifications (Stand Alone Gauge) |
Gauge Type |
Digital Vacuum Gauge (use as standalone gauge, or pair with a mobile device) |
Sensor Type |
Self - heated thermistor bridge [with integral temperature compensation from 32° F to 122° F (0 to 50° C)] |
Accuracy |
Up to 2,000 microns = 10% of reading +/- 5 microns |
Resolution |
2000 microns : 98000 to 76000 |
50 microns : 9950 to 5000 |
1000 microns : 75000 to 50000 |
20 microns : 4980 to 1000 |
500 microns : 49500 to 25000 |
10 microns : 990 to 100 |
100 microns : 24900 to 10000 |
1 micron below 100 |
Display Type (Gauge) |
LCD, 5 Digit |
Display Auto-Off |
10 minutes = default if no key pressed, no wireless connection, gauge not logging data |
Operating Range |
Atmospheric pressure to 0 microns |
Selectable Vacuum Units (Gauge & Wireless Device) |
Microns, Millibar, Inches Hg, Torr |
Maximum Working Pressure |
450 PSIG MWP, 3000 PSIG Burst (Connect to system only at 0 PSIG) |
Operating Temperature Range (Compensated) |
Accuracy as stated: 32°F to 122°F (0°C to 50°C) |
Operating Temperature Range (Non-Compensated) |
Add +/- 0.5% error for every °C |
Operating Temperature Range (Outside Compensated) |
-22° F to 158° F (-30° C to 70° C) |
Operating & Storage Humidity |
0 to 95%, Non-condensing |
Storage Temperature Range |
-40° F to 185° F (-40° C to 85° C) |
Battery Type |
One 9V Alkaline Battery (ANSI 1604AC - IEC 6LR61), included |
Battery Life |
Up to 20 hours continuous use |
Battery Level Indicator |
Battery symbol with 3 segments |
Gauge Weight |
5.5 oz (156 g) |
Mechanical Connection (Stainless Steel) |
Standard 1/4" female SAE refrigerant hose with core depressor |
Gauge Adapter (Stainless Steel, Included) |
1/4" SAE Male to 1/4" SAE Male to 1/4" SAE Female |
Refrigerant Gas Compatibility |
All (Including Ammonia) |
Dimensions (Dia. x Depth x Height) |
2.8" x 1.5" x 4.5" (71 mm x 38 mm x 114mm) |
Approvals |
FCC, CE, ICES |
Origin |
Designed and manufactured in USA with US and globally sourced components |
Warranty |
1 Year |
Specifications (When used with CPS LINK™ APP & MOBILE DEVICE) |
Gauge To Wireless Device Connection |
Patented Wireless CPS Link™ Technology (US Patent No. 9,043,161) |
Wireless Range |
Power: High = up to 250 ft. (76 m); Normal = Up to 175 ft. (53 m); Low = Up to 100 ft. (30 m) |
Frequency Range |
2.4 Ghz, ISM Band (Worldwide) |
Auto-Off |
10 minutes = defult if no key pressed, no wireless connection, gauge not logging data |
Battery Indicator |
Green = >40%; Yellow = >15%; Red = <15% |
Selectable Languages |
English, Espanol, Francais, Deutsch, Portuguese, Japanese, Russian, Hungarian |
Perform Vacuum Tests |
Time, Target, Dynamic, Static |
Custom Alarms |
To occur during vacuum tests |
Create Client List |
Enter and retain client information (name, address, phone, e mail, etc.) |
Job Tracker |
Create and retain record of services performed (vacuum tests, maintenance, new installation, etc.) |
Job Checklist |
Create and retain checklists (task reminders) for reference on current or future jobs |
Log Data |
Record vacuum test data (real time graphs) |
Geolocation |
Record (global) geographic co-ordinates and "time stamp" when/where job was performed |
Create Invoice |
Create and retain job invoices (with job data) |
Share Data (E-Mail) |
Conveniently store or send all data/job (files) to clients, home office, etc. |
Cloud Backup |
Securely back up all data on the cloud |