Input voltage |
90 – 264 V (50/60 Hz) |
Power consumption |
Max. 70 VA |
Display |
LCD colour display (320 x 240) |
Data interface |
•USB 2.0 (type B plug)
•BAUR Report Manager external USB interface (type A plug) |
Printer |
Matrix printer, 24 characters, 57 mm plain paper |
Ambient temperature (operational) |
-10°C to +55°C |
Storage temperature |
-20°C to +60°C |
Humidity |
Non-condensing |
Dimensions (W x H x D) |
545 x 458 x 380 mm (closed)
545 x 770 x 461 mm (open) |
Weight |
Approx. 39 kg |
Degree of protection |
IP 32 |
Safety and EMC |
CE-compliant in accordance with Low Voltage Directive (2014/35/EC), EMC Directive (2014/30/EC), EN 60068-2-ff Environmental testing |
Software available in |
German, English, French, Spanish, Portuguese, Italian, Russian, Czech, Polish, Dutch, Chinese (CN), Chinese (TW), Korean |
Insulating oil testing |
Output voltage |
0 – 100 kVrms symmetrical |
Voltage slew rate |
0.5 – 10 kV/s |
Switch-off time |
< 10 μs |
Voltage slew monitoring |
Real Breakdown Monitoring (RBM) |
Accuracy |
0 – 100 kV ± 1 kV |
Resolution |
0.1 kV |
Internal temperature recording of the oil sample |
0 – 99°C |
Temperature resolution |
1°C |
Test standards |
ASTM D1816:2012 1 mm, ASTM D1816:2012 2 mm, ASTM D1816/97, ASTM D877/D877M:2013 PA, ASTM D877/D877M:2013 PB, BS EN 60156, CEI EN 60156, CSSR RVHP:1985, IEC 60156:1995, IRAM 2341:1972, JIS C2101:2010, PN 77/E-04408, SEV EN 60156, UNE EN 60156, NF EN 60156, SABS EN 60156, VDE 0370 Part 5:96, AS 1767.2.1 |
User-specific test sequences |
10 |