Size |
5.1 x 2.8 x 2.0 in. / 13.1 x 7.0 x 5.2 cm |
Weight |
11.5 oz. / 328 g |
Temperature |
-4 to 122ºF / -20 to 50ºC |
Humidity |
10 - 100% RH (non-condensing) |
Alarms |
- Visual, vibrating, audible (95dB)
- Low, High, STEL, TWA, OL (over limit), Low Battery, Pump |
Tests |
Audible/visual alarms on activation, sensors, battery, pump and circuitry (continuous) |
Typical battery life |
13 hours @ 32ºF / 0ºC
8 hours @ -4ºF / -20ºC
Recharges in 6 hours |
Pump draw |
Sample from up to 75 ft. / 23 m |
User options |
Confidence beep |
Force calibration when overdue |
Safety (sensor) lock |
Sensor configuration |
Latching alarms |
Detector identification |
Safe display mode |
Low alarm acknowledge |
Calibration IR lock |
Language choices (five) |
Location selection |
Set custom start-up message |
Force block test |
Confidence interval |
Force bump test when overdue |
Datalog interval |
|
Ratings Ingress Protection |
EMI/RFI: Complies with EMC Directive 2004/108/EC IP66/67 |
Certifications and approvals |
Class I, Div. 1, Gr. A, B, C, D
IECEx: Ga Ex ia IIC T4
ATEX: II 1 G Ga Ex ia IIC T4
Br Ex ia IIC T4 |
Warranty |
Full two year warranty including all sensors |
Gas |
Measuring Range |
Resolution |
H2S |
0-200 ppm |
1 ppm |
CO |
0-1000 ppm |
1 ppm |
O2 |
0-30.0% |
0.1% |
Combustible gases |
0-100% LEL
0-5.0% v/v
|
0.1%
1%
|
Alarm setpoints for all sensors are user adjustable. Setpoint(s) are automatically displayed during instrument start-up. |
Operating temperature |
-20°C to +50°C (-4°F to +122°F) |
Storage temperature |
-40°C to +60°C (-40°F to +140°F) |
Operating humidity |
10% to 100% relative humidity (non-condensing) |
Dust and moisture ingress |
IP66/67 |
Alarm setpoints |
May vary by region and are user-defined |
Detection range |
H2S: 0 - 200 ppm (1 ppm increments)
CO: 0 - 1000 ppm (1 ppm increments)
O2: 0 - 30.0% vol. (0.1% vol. increments)
Combustible (LEL): 0 - 100% (1% LEL increments) or
0 - 5.0% v/v methane |
Sensor type |
H2S, CO, O2: Single plug-in electrochemical cell |
Combustibles |
Plug-in catalytic bead |
O2 measuring principle |
Capillary controlled concentration sensor |
Alarm conditions |
TWA alarm, STEL alarm, low alarm, high alarm, multi-gas alarm, over limit (OL) alarm, low battery alarm, confidence beep, automatic deactivation alarm, and pump alarm |
Audible alarm |
95 dB+ at 30 cm variable pulsed beeper with full battery charge |
Visual alarm |
Red light-emitting diodes (LEDs) |
Display |
Alphanumeric liquid crystal display (LCD) |
Backlight |
Activates upon startup and when the pushbutton is pressed; deactivates after 10 seconds. Also activates during an alarm condition and remains lit until alarm ceases |
Self-test |
Initiated at activation and tests continuously |
Calibration |
Automatic zero and automatic span |
User field options |
Startup message, lockout on self-test error, safe mode, confidence beep, latching alarms, force calibration, cal IR lock, force bump, location logging, force block test, set datalog interval, set confidence interval, language selection |
Sensor options |
Sensor enable/disable, set span calibration values, set calibration interval, set bump interval, set alarm setpoints, set STEL interval, set TWA period, auto zero at startup enable/disable, 5% over span, low alarm acknowledge, oxygen measurement, and combustible gas measurement |
Battery operating time |
One rechargeable lithium polymer: 13 hours (typical) |
Year of manufacture |
The detector's year of manufacture is determined from the serial number. The second and third number after the second letter determines the year of manufacture. E.g., MA 110-000001 = 2010 year of manufacture |
Approved batteries |
North America Approved batteries for GasAlertMax XT II product |
Lithium-ion polymer battery as per standards EN50020, UL913, C22.2 No. 157 |
Rechargeable battery (MX-BAT01) |
Lithium polymer |
Temperature code |
-20°C ≤ Ta ≤ +50°C T4 |
Battery charger |
charging adapter |
First-time charge |
6 hours |
Normal charge |
6 hours |