Technical Specifications |
Honeywell BW MICROCLIP XL |
Honeywell BW MICROCLIP X3 |
Size |
11.3 x 6.0 x 3.2 cm / 4.4 x 2.4 x 1.2 in |
Weight |
190 g / 6.7 oz. |
179 g / 6.3 oz |
Temperature |
-20 to +50°C / -4 to +122°F |
Humidity |
0% - 95% RH (non-condensing) |
Alarms |
Visual, vibrating, audible (95 dB) • Low, High, TWA, STEL, OL (over limit) |
Test |
Audible/visual alarms on activation; sensors, battery and circuitry (continuous) |
Typical Battery life |
18 hours; recharges in less than 6 hours
Note: Approximately 20% capacity loss is normal with lithium polymer batteries after 500 charge cycles. Refer to the Operator’s Manual for additional information. |
Pump Draw |
Compatible with the Sampler motorized sampling pump |
User Option |
• Confidence beep
• Set STEL interval
• Sensor on/off
• Latching alarms
• Safe display mode
• Stealth mode
• Calibration lock
• Auto zero on start up
• O2 auto calibration on start up
• Set bump test interval
• Force bump test when overdue |
• IntelliFlash™ interval
• Combustible gas measurement (%LEL or % by volume methane)
• User-settable calibration gas level
• Force calibration when overdue
• Low alarm acknowledge
• Language choices
• Set custom start up message
|
Ratings Ingress Protection |
IP68 – up to 45 minutes at 1.2 m (Honeywell BW™ MicroClip XL and X3) EMI/RFI: Complies with EMC Directive 2004/108/EC |
Certifications and Approvals |
|
Warranty |
Full two‑year (Honeywell BW™ MicroClip XL) or three‑year (Honeywell BW™ MicroClip X3) warranty including all sensors
Note: Battery is guaranteed to have 12 hour runtime during warranty period under normal operating temperature of 4°F / -20°C to 122°F / 50°C. |
Expected Service Lifetime |
Five years including all sensors* (Honeywell BW™ MicroClip X3 only) *Note: Sensors do not contain consumable components and will typically reach the expected lifetime if used according to the instructions in the user manual. Please note that poisoned sensors are not covered by warranty |