BW M5PID-XUQY-R-D-D-Y-N-00 General Specifications |
Instrument dimensions |
14.5 x 7.4 x 3.8 cm (5.7 x 2.9 x 1.5 in.) |
Temperature |
Weight |
370 g (13.1 oz.) |
VOC |
-10°C to +40°C (-14°F to +104°F) |
Other gases |
-20°C to +50°C (-4°F to +122°F) |
Combustible gas sensor |
Certified by CSA International to ±3% LEL accuracy from -10°C to +40°C (4°F to 104°F) |
Humidity |
O2 |
0% to 99% relative humidity (non-condensing) |
VOC and CO2 IR |
0% to 95% relative humidity (non-condensing) |
Combustibles |
5% to 95% relative humidity (non-condensing) |
Cl2 |
10% to 95% relative humidity (non-condensing) |
HCN, ClO2 |
15% to 95% relative humidity (non-condensing) |
Other gases |
15% to 90% relative humidity (non-condensing) |
Pressure |
95 to 110 kPa |
Alarm setpoints |
May vary by region and are user-defined |
Detection range
|
O2 |
0 – 30.0% vol. (0.1% vol. increments) |
CO |
0 – 999 ppm (1 ppm increments) |
CO (TwinTox sensor) |
0 – 500 ppm (1 ppm increments) |
H2S |
0 – 500 ppm (1 ppm increments) |
H2S (TwinTox sensor) |
0 – 500 ppm (1 ppm increments) |
Combustible (LEL) |
0 - 100% LEL (1% LEL increments) or 0 - 5.0% v/v methane; certified by CSA International to C22.2 No. 152 and ISA 12.13.01 within 0 - 60% or 3.0% v/v methane |
PH3 |
0 – 5.0 ppm (0.1 ppm increments) |
SO2 |
0 – 150 ppm (1 ppm increments) |
Cl2 |
0 – 50.0 ppm (0.1 ppm increments) |
NH3 |
0 – 100 ppm (1 ppm increments) |
NO2 |
0 – 99.9 ppm (0.1 ppm increments) |
HCN |
0 – 30.0 ppm (0.1 ppm increments) |
ClO2 |
0 – 1.00 ppm (0.01 ppm increments) |
O3 |
0 – 100 ppm (0.01 ppm increments) |
VOC |
0 – 1000 ppm (1.0 ppm increments) |
CO2 IR |
0-50,000 ppm (50 ppm increments) or 0-5.0% v/v CO2(Sensors not available for use with the Micro 5 IR: ClO2, HCN, NO2, PH3, and Cl2) |
Sensor type |
H2S/CO |
Twin plug-in electrochemical cell |
Combustibles |
Plug-in catalytic bead |
VOC |
Photoionization detector (PID) |
CO2 |
IR detector |
Other gases |
Single plug-in electrochemical cell |
O2 measuring principle |
Capillary controlled concentration sensor |
Alarm conditions |
TWA alarm, STEL alarm, low alarm, high alarm, multi alarm, over limit alarm, sensor alarm, pump alarm, MMC/SD card fail alarm, low battery alarm, confidence beep, automatic deactivation alarm |
Audible alarm |
95 dB at 0.3 m (1 ft.) variable pulsed dual beepers |
Visual alarm |
Dual red light-emitting diodes (LED) |
Display |
Alphanumeric liquid crystal display (LCD) |