General Specification |
SIZE |
2.7 x 2.6 x 1.4 in. / 7.0 x 6.7x 3.6 cm (1-Series sensor models)
2.7 x 2.6 x 1.6 in. / 7.0 x 6.7x 4.1 cm (4-Series sensor models) |
WEIGHT |
3.6 to 4.1 oz. / 103 to 116 g, depending on installed sensor |
HUMIDITY |
0% - 95% RH (non-condensing) |
INGRESS PROTECTION |
IP66/68 |
ALARMS AND TYPE |
Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, non-compliance |
SELF-TEST |
Sensor integrity, circuitry, battery and audible/visual alarms on activation; battery (continuous) |
TYPICAL BATTERY LIFE |
12 months (6 months for 1-Series O2) |
CONNECTED WORKER |
Bluetooth™ Low Energy (BLE) – Ability to connect to Honeywell’s Safety Communicator App |
USER OPTIONS |
•Reset TWA, STEL and Peak readings
•Change High, Low, TWA and STEL alarm setpoints
•Latching alarms
•Enable IntelliFlash and non-compliance indicators
•Set calibration and/or bump test reminders
•Assign worker and location assignments
•Language select: English, French, Spanish, German, Italian, Russian, Japanese, Chinese, Korean, Portuguese, Dutch |
CERTIFICATIONS AND APPROVALS |
•CSA
Class I, Division 1, Groups A, B, C, D T4
Class I, Zone 0, AEx/Ex ia IIC T4 Ga -40°C≤ Tamb ≤ 60°C
•ATEX
Sira 18ATEX2243
CE 2460 g II 1G Ex ia IIC T4 Ga
Ex ia I Ma -40°C≤ Tamb ≤ 60°C
•IECEx
IECEx SIR 18.0058
Ex ia IIC T4 Ga / Ex ia I Ma -40°C≤ Tamb ≤ 60°C
•FCC ID
SU3BWS1
•IC
20969-BWS1
•RED
RE-D Directive 2014/53/EU |
WARRANTY |
3 years for 1-Series detectors and sensors (H2S, CO, O2)
2 years for 4-Series detectors and sensors (1 year for NH3, Cl2, O3, ETO, ClO2 sensors) |
Sensor Specification |
Gases |
Cl2 (4s) |
Standard Measuring Range |
0-50 ppm |
Resolution |
0.1 ppm |
Operating Temperature |
-4 to +104°F /
-20 to +40° |