| Material |
Polycarbonate with tough rubber overmold |
| Weight (Alkaline) |
1.1 lbs/17.6 oz/499 g (5 sensors) |
| Weight (Alkaline) + Pump |
1.4 lbs/22.4 oz/635 g (5 sensors) |
| Weight (Lithium-Ion) |
1.0 lbs/16 oz/454 g (5 sensors) |
| Weight (Lithium-Ion) + Pump |
1.3 lbs/20.8 oz/590 g (5 sensors) |
| Dimensions w/o std belt clip |
6.63 x 3.13 x 2 in./16.83 x 7.94 x 5.08 cm |
| Dimensions with std belt clip |
6.63 x 3.13 x 2.5 in./16.83 x 7.94 x 6.35 cm |
| Dimensions w/o std belt clip, with pump |
8.5 x 3.13 x 2.38 in./21.59 x 7.94 x 6.03 cm |
| Dimensions with std belt clip and pump |
8.5 x 3.13 x 2.63 in./21.59 x 7.94 x 6.66 cm |
| Type |
Rechargeable Lithium Ion or Alkaline (3 x AA size) battery pack options |
| Dust & Water Resistance Rating |
IP65 |
| Drop Testing |
Dropped 100+ times from 1 meter to concrete ß oor |
| RF Immunity |
Conforms to EN 50270 |
| RF Emissions |
Conforms to IEC 61000-6-4 |
| ESD Immunity |
Conforms to IEC 61000-4-2 |
| Charger (all models) @ 68ºF (20ºC) |
6 hrs max. |
| |
SGS/USTC Class I, Division 1, Groups A,B,C,D Temp Code T3C |
| |
SGS/USTC Class II, Division 1, Groups E,F,G, Class III |
| |
CSA Class I, Division 1, Groups A,B,C,D Temp Code T3C (CSA approval does not include IR sensor) |
| |
ATEX (EPS) Ex ia d IIC 170C (T3) |
| |
IECEx Ex ia d IIC 170C (T3) |
| |
CE Mark |
| |
Capabilities |
| Controls |
3 buttons |
| Sensor Channels |
Maximum of 6 |
| Available Sensors |
O2, LEL, PID, Duo-Tox, CO, H2S, CO-H, SO2, Cl2, NO, NO2, NH3, PH3, HCN, IR-CO2, IR-CH4 |
| User adjustable alarms |
Oxygen: Danger Low/Danger High; Combustible: Warning/Danger; PID and Toxic: TWA/STEL/Warning/Danger |
| Calibration |
Fresh air and gas calibration with one button |
| Calibration dates |
Most recent for full instrument calibration and for each sensor |
| Motorized pump |
Optional external pump, standard length 10 ft. (3 m), maximum length 100 ft. (30 m) |
| Security Beep |
User adjustable interval from 5 seconds to 60 minutes |
| Latching Peak Alarms |
User enabled |
| Datalogging |
Blackbox datalogger that can be upgraded to a full datalogger at any time. Activation code and BioTrak PC software required. Full datalogger has user adjustable interval from 1 second to 60 minutes. |
| Datalogging capacity |
See table |
| Computer Interface |
IrDA |
| Event Logger |
20 events including max, min, and average for all sensors, time and duration |
| Visual |
Bright red LED alarm visible from top and sides |
| Audible |
Dual Piezoelectric audible alarm, 92 dbA @ 1 foot (30.5 cm) PhD6 Alarm Loudness Test |
| Vibrating |
Optional |