| BW ToxiPro General Specifications |
| Housing |
Weight |
3.5oz (99 grams) |
| Size |
3.325 in. (8.44cm) x 2.19 in. (5.56 cm) x 1.16 in. (2.95 cm) |
| Case Material |
Clear polycarbonate with TPE overmold |
Dust and Water
Resistance Rating |
IP66/IP67 |
Environmental
Ratings |
RF Immunity |
Conforms to EN 50270 |
| RF Emissions |
Conforms to IEC 61000-6-4 |
| ESD Immunity |
Conforms to IEC 61000-4-2 |
| Approvals |
UL Class I, Div 1, Group A,B,C,D T4 |
| UL Class II, Div 1, Group E,F,G |
| CSA Class I, Div 1, Group A,B,C,D T4 |
| CSA Class II, Div 1, Group E,F,G |
| ATEX (DEMKO) II 1 G Ex ia IIC T4 |
| IECEx Ex ia IIC T4 Ga |
| CE Mark |
| CQST (China) Ex ia IIC T4 |
| Backlight |
Type |
Multi-color LED Backlight |
| Gas Types |
Available Sensors |
CO, CO-H, H2 S, O2 , SO2 , PH3 , NH3 , CL2 , HCN, NO |
| Alarm Levels (default) |
|
| Warning alarm (ppm) |
35 |
10 |
23.5 |
2 |
0.5 |
25 |
1 |
0.3 |
4.7 |
| Danger alarm (ppm) |
100 |
20 |
19.5 |
5 |
1 |
35 |
5 |
1 |
4.7 |
| TWA alarm (ppm) |
35 |
10 |
na |
2 |
0.5 |
25 |
1 |
0.3 |
4.7 |
| STEL alarm (ppm) |
100 |
15 |
na |
5 |
1 |
35 |
1 |
1 |
4.7 |
| Ranges |
CO |
0-999 |
| CO-H |
0-999 |
| H2 S |
0-200 |
| SO2 |
0-100 |
| O2 |
0-30 |
| CL2 |
0-20 |
| NH3 |
0-100 |
| NO2 |
0-20 |
| HCN |
0-100 |
| PH3 |
0-20 |
| Resolution |
CO |
1 ppm |
| CO-H |
1 ppm |
| H2 S |
1 ppm |
| SO2 |
0.1 ppm |
| O2 |
0.1%/Vol |
| CL2 |
0.1 ppm |
| NH3 |
1 ppm |
| NO2 |
0.1 ppm |
| HCN |
0.1 ppm |
| PH3 |
0.01 ppm |
| Battery |
Battery Life |
9000 hrs. |
| Shelf Life |
4000 hrs. |
| Type |
Lithium Manganese Dioxide |
| Battery Replaceable |
Yes |
| Reverse Battery Protection |
Yes |
| Datalogging |
Number of sessions |
up to 100 |
| Number of Intervals |
up to 8100 |
| Number of Events |
100 |
| Blackbox datalogger |
up to 8100 intervals at 1 minute
Can be upgraded to a full datalogger at any time. Activation code and BioTrak PC software required. |
| Instrument |
Temperature range |
(Continuous — storage) 0 to 110ºF (-18 to 43ºC) |
| Temperature range |
(Intermittent <30 minutes; H2 S) -40 to 140ºF (-40 to 60ºC) |
| Temperature range |
(Intermittent <30 minutes; Others) -20 to 120ºF (-29 to 49ºC) |
| Humidity Range |
15 - 95% RH, non-condensing (0 - 95% RH <= 4 hours) |
| Alarm Sound Levels (Two Tone) |
100+ dB @ 10cm |