Ranges: 400 mV, 4 V, 40 V, 400 V, 1000V Resolution: 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V Accuracy: ?(1.0 % rdg + 2 dgts) Input Impedance: 400 mV: 100 MO; 4 V: 10 MO; 40 V to1000 V: 9.1 MO Overload Protection: 1000 VDC or 750 VACrms Ranges: 400 mV, 4 V, 40 V, 400 V, 750V Resolution: 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V Accuracy: 400 mV range at 50 Hz to 100 Hz ?(2.0 % rdg + 5 dgts) Input Impedance: 400 mV: 100 MO; 4 V: 10 MW; 40 V to 750 V: 9.1 MO Overload Protection: 1000 VDC or 750 VACrms Ranges: 400 uA, 4000 uA, 40 mA, 400 mA, 10 A Resolution: 0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA Accuracy: 400 uA to 400 mA ranges: ?(2.0 % rdg + 2 dgts)10 A range: ?(3.0 % rdg + 3 dgts) Input Protection: 0.5 A/500 V & 10 A/600 V fast blow ceramic fuses 10A Input: 10 A for 60 sec max. followed by a 10 minute cooling period Ranges: 400 uA, 4000 uA, 40 mA, 400 mA, 10 A Resolution: 0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA Accuracy: 20 mA to 200 mA ranges: ?(2.0 % rdg + 8 dgts)10 A range: ?(3.5 % rdg + 8 dgts) Input Protection: 0.5 A/500 V & 10 A/600 V fast blow ceramic fuses 10A Input: 10 A for 60 sec max. followed by a 10 minute cooling period Ranges: 400 O, 4 kO, 400 kO, 40 MO Resolution: 0.1 O, 1.0 O, 100 O, 10 kO Accuracy: 400 O to 400 kO ranges: ?(1.5 % rdg + 4 dgts)4 MO range: ?(2.5 % rdg + 4 dgts)40 MO range: ?(5.0 % rdg + 4 dgts) Open Circuit Voltage (typical): -0.45 VDC (-1.2 VDC on 340 O range) Overload Protection: 500 VDC/ACrms Test Current: 1.0 mA (typical) Resolution: 10 mV Accuracy: ?(3.0 % rdg + 3 dgts) Audible Indication: 0.25 V Open Circuit Voltage: 3.0 VDC (typical) Overload Protection: 500 VDC/ACrms Audible Indication: Less than 25 O Response Time: 500 ms Overload Protection: 500 VDC/ACrms |