Associated Research Hipot Tester

 
Associated Research 03870 - AC/DC Hipot with Insulation Resistance
  • Test Type Hipot: AC, DC, IR
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Max Trip Current AC Test: 20 mA
  • Max Trip Current DC Test: 7.5 mA
  • Product Weight: 12 LBS

Your Price: $2,699.00

In Stock:
  • View Payment Options
Associated Research 07850 - HypotULTRA, AC/DC Hipot with Insulation Resistance
  • Test Type Hipot: AC, DC, IR
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Max Trip Current AC Test: 30 mA
  • Max Trip Current DC Test: 10 mA
  • Product Weight: 35 LBS

Your Price: $5,149.00

In Stock:
Associated Research 03865 - AC/DC Hipot, 5 kV @ 20 mA AC, 6 kV @ 7.5 mA DC
  • Test Type Hipot: AC, DC
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Max Trip Current AC Test: 20 mA
  • Max Trip Current DC Test: 7.5 mA
  • Product Weight: 12 LBS

Your Price: $2,399.00

In Stock:
Associated Research 07820 - HypotULTRA, AC Hipot Tester
  • Test Type Hipot: AC
  • Max AC Test Voltage: 5 kV
  • Max Trip Current AC Test: 30 mA
  • Product Weight: 34 LBS
  • Product Height: 3.50 IN
  • Product Length: 15.75 IN

Your Price: $4,119.00

In Stock:
Associated Research 03805 - AC Hipot Tester, 5 kV @ 20 mA
  • Test Type Hipot: AC
  • Max AC Test Voltage: 5 kV
  • Max Trip Current AC Test: 20 mA
  • Product Weight: 12 LBS
  • Product Height: 3.5 IN
  • Product Length: 11.9 IN

Your Price: $1,899.00

In Stock:
Associated Research 07705 - AC Hipot Tester, 10 kV @ 20 mA
  • Test Type Hipot: AC
  • Max AC Test Voltage: 10 kV
  • Max Trip Current AC Test: 20 mA
  • Product Weight: 61.65 LBS
  • Product Height: 5.24 IN
  • Product Length: 15.75 IN

Your Price: $7,299.00

In Stock:
Associated Research 07710 - DC Hipot Tester, 12 kV @ 10 mA DC
  • Test Type Hipot: DC
  • Max DC Test Voltage: 12 kV
  • Max Trip Current DC Test: 10 mA
  • Product Weight: 61.65 LBS
  • Product Height: 5.24 IN
  • Product Length: 15.75 IN

Your Price: $7,299.00

In Stock:
Associated Research 07715 - AC Hipot Tester, 20 kV @ 10 mA AC
  • Test Type Hipot: AC
  • Max AC Test Voltage: 20 kV
  • Max Trip Current AC Test: 10 mA
  • Product Weight: 48.9 LBS
  • Product Height: 5.24 IN
  • Product Length: 15.75 IN

Your Price: $9,299.00

In Stock:
Associated Research 07720 - DC Hipot Tester, 20 kV @ 5 mA DC
  • Test Type Hipot: DC
  • Max DC Test Voltage: 20 kV
  • Max Trip Current DC Test: 5 mA
  • Product Weight: 48.9 LBS
  • Product Height: 5.24 IN
  • Product Length: 15.75 IN

Your Price: $9,299.00

In Stock:
Associated Research 07800 - HypotULTRA, AC/DC Hipot with Insulation Resistance
  • Test Type Hipot: AC, DC, IR
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Max Trip Current AC Test: 100 mA
  • Max Trip Current DC Test: 10 mA
  • Product Weight: 45 LBS

Your Price: $6,499.00

In Stock:
Associated Research 07804 - HypotULTRA, AC/DC Hipot with Ground Bond and Insulation Resistance
  • Test Type Hipot: AC, DC, Ground Bond, IR
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Max Trip Current AC Test: 30 mA
  • Max Trip Current DC Test: 20 mA
  • Product Weight: 41 LBS

Your Price: $8,239.00

In Stock:
Associated Research 07854 - HypotULTRA, AC/DC Hipot with Ground Bond and Insulation Resistance
  • Test Type Hipot: AC, DC, Ground Bond, IR
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Max Trip Current AC Test: 100 mA
  • Max Trip Current DC Test: 20 mA
  • Product Weight: 46.30 LBS

Your Price: $8,999.00

In Stock:
null
null
null
null
null
null
null
null
null
null
null
null

Recommended for you

Associated Research Hipot Tester

Hipot Testers are High Voltage testing instruments used predominately to test and confirm product specifications, as well as electrical breakdown limits. Hipots are also referred to as High Voltage Testers, Dielectric Testers, Dielectric Withstand, or Breakdown Testers. One of the primary differences between a Hipot Tester and an Insulation Resistance Tester is that the Hipot Tester will be used for evaluation and destructive testing. An IR Tester (Insulation Resistance Tester) is primarily used for insulation evaluation only.
 
Although the instrument is used for testing insulation in finished electrical equipment and cables, it may also be used to check the electrical integrity and quality of motors, switchgear, transformers and capacitors. The primary purpose of using a Hipot Tester is confirming whether the insulation is within specification. It is a requirement of most safety regulation agencies like IEC, UL, CSA, OSHA, ANSI, and CE  that manufactured electrical products and systems meet specified safety standards. The safety of all personnel, consumers or homeowners is the primary objective. It is a required test for industrial and consumer appliances and electrical products and very commonly found on a production lines.

Types of Hipot Testers   
  • AC Hipot Test
  • DC Hipot Test
Test voltages are selected based on the equipment being tested and the type of test being applied. Voltage ranges extend from as low as 500 Volts to over 50KV. The choice of voltage range is based on both the product being tested and specific application. The primary test requires a high voltage (higher than the normal operating voltage) be applied and a constant current. The outcome of the test is to evaluate the acceptable specification ranges, as well as possible breakdown ranges.

When selecting a Hipot tester, both the maximum voltage and maximum current required to meet the safety standards that have been predetermined for the product class and product category must be known. Trip-current ranges are normally between 20 and 100 milliamps. Some special order units can be made to fit the exact requirements of your test.

Comparing DC Hipot vs AC Hipot (While AC Hipots may be more popular, when is a DC Hipot needed?)

DC Hipot Test Advantages
  • Since a DC Hipot applies exactly the recommended voltage and does not cycle between positive and negative peak voltages, it is effective regardless of the product or system capacitance.
  • In highly capacitive circuits, DC testing will charge the capacitor where it might trip with an AC tester and not be possible to test at all.
  • In order to protect the system, "Y" capacitors are frequently used by instrument/appliance manufactures to protect DC electronics. They protect controls and computers against high frequency surges and RF noise in the AC line by shunting noise to ground. An AC Hipot that normally charges from positive voltage to zero and then negative voltage will have a harder time providing the test with Y capacitors in the ciurcuit, than a DC Hipot.
  • The current trip for the leakage may be set on a significantly lower value. The manufacturer may then identify and remove products with marginal insulation that may have otherwise passed.
DC Hipot Test Disadvantages
  • Only one direction of polarity can be tested with DC
  • Not all test standards consider DC testing to be on the same par as AC testing. While most standards allow either, testing of large motors is still by AC Hipots. There are some very old legacy standards that predate the availability of DC Hipots
  • Unlike its AC counterpart, the DC Hipot test cannot replace the test for line voltage leakage
AC Hipot Test Advantages
  • AC testing checks both polarities of voltage. Products that use AC for normal operation should not be tested by a DC Hipot
  • Information with an AC Hipot is instantaneous. DC Hipot testers require a few seconds at the end of each test to discharge the internal capacitor. Although not normally a problem, it may be a consideration when testing time is of the essence, as in a production line
  • AC testing is accepted by all test standards
AC Hipot Test Disadvantages
  • Since an AC source for testing produces a peak positive and negative signal, highly capacitive circuits may reduce the accuracy and timing of the test and interfere with leakage and tripping current. (see first bullet for DC Hipot Advantages)
  • Since AC testing actually applies a peak positive voltage as well as a peak negative voltage and then cycles between each, the current produced during testing is greater and may actually weaken the insulation being tested. This in turn may cause failure of the product either in normal use. We welcome your comments on your experience.
Download a detailed white paper on AC Hipots from Phenix Technologies: Phenix AC Dielectric Paper

Insulation Resistance Test (High Resistance Test aka IR Tester, Megaohm Meter, Megger)

Please note that an IR Tester is NOT a substitute for a Hipot Tester, but the IR test may be included as an optional test capability on selected Hipot Units. If you require both tests, review your product selection.

The safety of electrical wiring insulation is tested using Megohmmeters / Insulation Resistance Testers (IR Testers). Equipment damage, electrical shock, and fires can occur as electrical insulation breaks down. This is a high resistance test to see if the insulation on equipment is in good condition or in a possibly damaged and deteriorated condition. The test evaluates the condition of insulation or electrical isolation. The typical test applies a specified or calculated voltage at low current and measures the resistance in ohms. The ranges of resistance for a passing value can be from a few megohms to teraohms.  Often this test is done to provide predictive maintenance for failure of equipment, wire, and cable. 

If your application is not for a HiPot and instead for an IR Tester, please see our full IR department page:
Products > Micro-Ohmmeter / Milliohmmeter / Megohmmeter > Megohmmeter / Insulation Resistance Testers
And learn more from our Megohmmeter / IR Tester Buyer's Guide

 

Electrical Safety Test Methods for Equipment


Powered equipment from hand tools, appliances, industrial equipment, and instruments to medical devices and more are tested for electrical safety to various global standards.

For example, IEC 60990 Standard discusses the safety involving the flow of leakage or touch current through the human body. The effect of electric current on a human body can be extremely dangerous. It provides measuring methods for the four body responses:

• Perception
• Reaction
• Let-Go
• Electric Burn

JIS T 0601-1 is the Japanese modification of the existing IEC 60601-1 Safety Standard. IEC 60601-1 is the accepted standard for safety testing of all medical equipment. Both consider safety to be the primary concern.

Here are more standards to consider. Note: It is a partial list. Also, if a test instrument we offer does not specifically list a particular test method, that does not necessarily mean it cannot be used. Since there are so many test methods, the litereture may not enumerate them all. Please contact us with the specific method and we can research it for you.
 
Partial List of Global Electrical Safety Standards
ANSI / AAMI EC11 Diagnostic Electrocardiographic Devices U.S.
ANSI / AAMI EC13 Cardiac Monitors, Heart Rate Meters, and Alarms U.S.
ANSI / AAMI EC53 ECG Cables and Leadwires U.S.
ANSI / IEEE C37.60 High-voltage Switchgear and Controlgear U.S.
ANSI A92.2 Vehicle Mounted Elevating and Rotating Work Platforms U.S.
BS EN 61557 Electrical safety in low voltage distribution systems up to 1000VAC and 1500VDC British
BS 7671 Requirements for Electrical Installations, IEE Wiring Regulations British
DIN VDE 0701-0702 0701 Repair, Modification, and Inspection of Electrical Equipment. 0702 Periodic Testing of Electrical Equipment German
EN 55024 Information Technology Equipment Europe
GR-1089 Electromagnetic Compatibility and Electrical Safety - Generic Criteria for Network Telecommunication Equipment U.S.
IEC 384-14, Annex A, Table VXI Capacitors Europe
IEC 50144
BS EN 50144
Safety of Hand-held Electric Motor Operated Tools Europe/ British
IEC 60065 Audio, Video, and Similar Electronic Apparatus - Safety Requirements Europe
IEC 60204-1 Safety of Machinery Europe
IEC 60335-1 Safety of Electrical Household Appliances Europe
IEC 60601-1 Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance Europe
IEC 60601-2 Medical Electrical Equipment - Part 2: Particular Requirements for the Basic Safety and Essential Performance of Gamma Beam Therapy Equipment Europe
IEC 60745 Safety of Hand-operated Motor-driven Electric Tools Europe
IEC 60950-1 Safety of Information Technology Equipment Europe
IEC 60990 Methods of Measurement of Touch Current and Protective Conductor Current Europe
IEC 61010-1 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use Europe
IEC 61029 Safety of Transportable Motor-Operated Electric Tools Europe
IEC 61730-2 Photovoltaic (PV) Module Safety Qualification - Part 2 Requirements for Testing Europe
IEC 61813 Live Working - Care, Maintenance and In-service testing of Aerial Devices with Insulating Booms Europe
IEC 62052-11 Electricity Metering Equipment (AC) - General Requirements, Tests, and Test Conditions Europe
IEC 62353 Medical Electrical Equipment - Recurrent Test and Test After Repair of Medical Electrical Equipment Europe
IEC 62446 Grid Connected Photovoltaic Systems - Minimum requirements for System Documentation, Commissioning Tests and Inspection Europe
ITU-T K.20 Resistibility of Telecommunication Equipment Installed in a Telecommunications Centre to Overvoltages and Overcurrents Europe
ITU-T K.21 Resistibility of Telecommunication Equipment Installed in Customer premises to Overvoltages and Overcurrents Europe
JIS B8561 Vending Machines - Test Method Japan
JIS C9250 Microwave Ovens Japan
JIS T 0601-1 Electrical Safety Standard for Medical Devices Japan
TE-001, Para. 17 Telephone Surge Test Equipment: For the Lightning Protection Tests South Africa
TIA/EIA/IS-968 Telecommunications Telephone Terminal Equipment Technical Requirements for Connection of Terminal Equipment to the Telephone Network. (formerly known as FCC Part 68) U.S.
uL 492 Power-operated Radio Receiving Appliances U.S.
uL 746E Polymeric Materials - Industrial Laminates, Filament Wound Tubing, Vulcanized Fibre, and Materials Used In Printed-Wiring Boards (Section 19 covers requirements for conformal coatings used instead of electrical spacings to increase the dielectric withstand voltage between traces on a printed-wiring board.) U.S.
uL 2231-1 Standard for Safety for Personnel Protection Systems for Electric Vehicle (EV) Supply Circuits: General Requirements U.S.
uL 2231-2 Standard for Safety for Personnel Protection Systems for Electric Vehicle (EV) Supply Circuits: particular Requirements for Protection Devices for Use in Charging Systems U.S.


 
X