PERFORMANCE SPECIFICATIONS |
Accuracy Class (Span) |
Includes non-linearity (Terminal Point Method), hysteresis, non-repeatability: ±0.5%, ±1.0%
Best Fit Straight Line (BFSL): ±0.25%, ±0.4%
Non-linearity: ±0.5%, ±1.0% |
Interchangeability Durability |
10^8 cycles with negligible performance change |
Stability |
±0.5% Span/yr |
ENVIRONMENTAL SPECIFICATIONS |
Temperature Limits |
Storage: –54 to 121°C (–65 to +250°F)
Operating: –28 to 82°C (–20 to +180°F)
Comp. Range: –28 to 82°C (–20 to +180°F) |
Thermal Coefficients: (68°F (20°C) ref.) %Span/°F |
Accuracy Class |
0.5% |
1% |
ZERO
SPAN |
±0.028%
±0.028%
|
±0.04%
±0.04% |
ZERO
SPAN |
±0.014%(Optional)
±0.014%(Optional) |
N/A
N/A |
Humidity |
No performance effect at 95% relative
humidity – noncondensing |
FUNCTIONAL SPECIFICATIONS |
Standard Ranges (psi) |
0/45*
0/60*
0/100
0/150
0/200
0/300
0/500
0/750
0/1000
0/2000
0/3000
0/5000
0/7500*
0/10,000*
0/15,000*
0/20,000*
*1% accuracy ranges only. Consult factory for nonstandard ranges. |
Overpressure Limits (F.S.) |
|
45-2000 |
3000-5000 |
7500-20,000 |
Proof |
200% |
150% |
120% |
Burst |
800% |
300% |
150% |
Vibration Sweep |
Less than ±0.1%F.S. effect for 0-2000 Hz at 20 g’s in any axis |
Shock |
Less than ±0.05% F.S. effect for 100 g’s, 20ms shock in any axis |
Response Time |
Less than 5 ms |
Position Effect |
Less than 0.01% F.S. |
ELECTRICAL SPECIFICATIONS |
Output (Sensitivity) |
Varies from 6-18mv/V at full scale depending upon pressure range Consult factory for interchangeability within a particular pressure range |
Excitation |
3-10 Vdc regulated |
Supply Current |
1.4mA (nominal) |
Zero Offset |
±3mV/Vdc |
Bridge Resistance |
3500 ohms (nominal) |
Circuit to Case Insulation Resistance |
100 M ohms @ 50 Vdc |
PHYSICAL SPECIFICATIONS |
Weight |
2 oz (approx. without cable F1 Type) |
MATERIALS |
Socket |
300 series stainless steel |
Cable |
4˝ polyethylene coated, 30 AWG or UL
approved 36˝, shielded, vented cable (24 AWG) |
Diaphragm |
17-4 PH stainless steel |
Standard Process Connections: (316 stainless steel) |
1⁄8 NPT male or female
1⁄4 NPT male or female
1⁄4 SAE-J-514 (male)
1⁄4 AMINCO (female) required for pressures over
10,000 psi
Other connections available |