| PERFORMANCE SPECIFICATIONS |
| |
GC51 Gauge Pressure Transmitter |
| Accuracy |
±0.25% FS (URL)
(Accuracy includes the effects of linearity,
hysteresis, and repeatability) |
| Reference Condition |
23°C ±2° (73°F) |
| Stability |
±0.25% FS/year |
| Response Time |
30 msec |
| Output Resolution |
0.1% FS (URL) |
| Display |
Type: 4 digit, 10mm LCD with LED backlight
Accuracy: ± 0.25% FS (URL) + last digit |
| Ranges |
Standard Ranges (Compound):
–15 to 15psi, –15 to 30psi, –15 to 50psi
Standard Ranges (Gauge):
0-50psi, 100psi, 150psi, 300psi, 500psi, 1000psi,
1500psi, 3000psi, 5000psi, 7500psi |
| ENVIRONMENTAL SPECIFICATIONS |
| Temperature Limits |
Storage: –20 to 70°C (–4 to 158°F)
Operating: –10 to 60°C (14 to 140°F)
Compensated: –10 to 60°C (14 to 140°F) |
| Temperature Effects (–10 to 60°C) |
±0.02% FS (URL)/°C from 23°C reference |
| FUNCTIONAL SPECIFICATIONS |
| Overpressure (F.S.) |
| RANGE |
Proof |
Burst |
| 1500 psi and below |
200% |
500% |
| 3000, 5000 psi |
150% |
300% |
| 7500 psi |
120% |
150% |
|
| Vibration |
5g’s 150Hz |
| Shock |
10g’s 16ms |
| Output Signal |
4-20mA (2 Wire) |
| Supply Voltage |
12-32Vdc Loop Power |
Rangeablility / Adjustment
(Accuracy and output resolution based upon
full scale (URL) value)
|
Zero –10% to +110% FS
Span –10% to +110% FS
|
| Insulation Resistance |
50Vdc (>100Mohms) |
| CE Compliance |
EMC Directive 2004/108/EC
• IEC/EN 61326-1: 2006 (EMI Class A/ EMS Table 2)
• IEC/EN 61326-2-3: 2006 (Annex BB (Pressure Transducer)) |
| Pressure Connection |
1/4 inch Female NPT |
| Enclosure Material |
Epoxy coated aluminum |
| Enclosure Rating |
NEMA 4X / IP65 |
| Electrical Connection (Options) |
1/2 inch Female NPT conduit or
Cable Gland (Diameters 0.46 to 0.47 inch) |
| Weight |
1 lb |
| Mounting |
Mounting Bracket |
| Media |
Fluids and gases compatible 316SS and pH17-4 SS |