| Analog Output (1-5Vdc) |
| Accuracy |
± 1.0% FS (accuracy includes the effects of linearity, hysteresis and repeatability) |
| Response time |
50msec |
| Output resolution |
25mV |
| Analog scaling |
User may configure analog output scaling to any range within full scale of sensor range |
| Pressure Switch Output |
| Type |
NPN or PNP open collector up to 30Vdc/80ma |
| Setting accuacy |
± 1.0% F.S. |
| Number of contacts |
2 |
| Time delay |
5 msec −2.0 sec (by user) |
| Hysteresis |
variable (by user) |
| Switch setting |
User may adjust switch actuation & deadband to any points within full scale sensor range |
| Display |
| Type |
3 1⁄2 digit, 10mm LED |
| Accuracy |
± 1.0% FS ± last digit |
| Display setting |
User may re-configure display scaling, set to capture MIN or MAX value, and adjust display update rate |
| PSI Ranges |
| Standard Ranges (Gauge) |
0 to 50 psig, 100 psig, 150 psig, 300 psig, 500 psig, 1000 psig, 1500 psig |
| Standard Ranges (Compound) |
−15 to 15 psig,−15 to 75 psig, −15 to 150 psig, −15 to 300 psig |
| ENVIRONMENTAL SPECIFICATIONS |
| Temperature Limits |
| Storage |
−22 to 140°F (−30 to 60°C) |
| Operating |
−4 to 140°F (−20 to 50°C) |
| Compensated |
14 to 122°F (−10 to 50°C) |
| Temperature Effects |
| Zero/Span |
±0.03% F.S./F (±0.05% F.S./C) from 73°F (23°C) reference temperature |
| Humidity |
0-85% RH (Non-Condensing) |
| FUNCTIONAL SPECIFICATIONS |
| Proof Pressure |
2X range: 500 psi & below
1.5X range: 1000 psi & above |
| Burst Pressure |
8X range |
| CE compliance |
EN61326-1 2006, EN61326-2-3 2006 |
| ELECTRICAL SPECIFICATIONS |
| Power Supply Requirements |
| Supply voltage |
11-27Vdc |
| Current consumption |
30mA (max) |
| Switch Contacts |
(2) NPN or PNP open collector outputs
NPN Type: 30Vdc / 80mA (max)
PNP Type: voltage drop 1Vdc (max)/80mA (max) |
| MECHANICAL SPECIFICATIONS |
| Pressure Connection |
1⁄4 NPT (Male) |
| Enclosure |
ABS, polycarbonate, aluminum |
| Rating |
IP40 |
| Electrical Connection |
6ft cable pigtail |
| Weight |
Approx. 110 grams |
| Mounting |
Panel mounting bracket included (back connect only) |
| Media |
Fluids and gases compatible with 304 SS (sensor housing) and 17-4 pH SS (sensor diapragm) |