Models |
2074 (battery) |
2174 (loop) |
2274 (line) |
Accuracy |
0.25% Full Scale, Terminal Point Accuracy |
Case Size |
3 inch or 4-1/2 inch |
Case Material |
3 inch - Stainless Steel; 4-1/2 inch Fiberglass Reinforced Thermoplastic or Black Epoxy Coated Aluminum |
Wetted Parts |
17-4 PH stainless steel (sensor); 316 Stainless Steel (socket) |
Enclosure |
Weatherproof Nema4, IP65 |
Connection |
1⁄4 or 1⁄2 NPT, JIS, DIN, SAE, (1⁄2 NPT only with 41⁄2? case, others on application) |
Connection Location |
Lower, 3 o'clock, 9 o'clock, 12 o'clock, or Top |
Operating Temperature |
14/140°F (-10/60°C) |
Temp. Error (Zero & Span) |
0.04%/°F (<.02%°F Typical) |
Storage Temperature |
–4/158° (–20°/70°F) |
Type |
LCD |
# Digits |
5 |
Character Height |
3? case: 0.60?, 4-1⁄2? case: 0.88? |
Backlite |
Optional |
Bar Graph |
Yes |
Battery |
3" (2) AA Alkaline; 4-1/2" (2) C Alkaline |
Battery Life |
3" 1000+; 4-1/2" 3600+ hrs |
Agency Approvals |
Optional FM, CSA
Intrinsically Safe Class I, Div. 1, Groups A-G |
On/Off |
Manually turns unit on and off (auto off options
in menu) |
Zero/Clear |
Zeros display or clears min. and max. values
when displayed |
Min/Max |
Down Arrow Key: Stores min and max values, arrow key allows for scrolling thru menu items |
Menu Key |
Provides access to menu options |
Backlite (optional) |
Up Arrow Key (Backlite optional):
Manually turns backlite on and off (auto off options in menu), arrow key allows for five menu options. Up arrow key allows for scrolling thru menu options |
Enter |
Selects items in the menu |
Engineering Units |
12 units of measurement are available:
psi, In. H2O (with three temp. options: 20°C, 60°F, 4°C*), Ft. H2O, mPa, mBar, kPa, kg/cm2, Bar, inHg and mmHg |
Configuration Mode (Config) |
Allows for changes to default settings of gauge including zero disable
feature |
Bar Graph (Graph) |
Allows for adjustment of bargraph and optional 4-20 |
Auto Off (Off) |
Allows for changes to auto off of gauge, five options: Never, 2 min., 5 min., 15 min., 30 min |
Update Rate (Update) |
Four options: 100 ms, 200 ms, 500 ms, 1 sec |
Dampening (Damp) |
Six options: None, average, 2, 4, 6, 8 times per 100ms |
Backlite |
Five options: Never, 10 sec., 30 sec., 1 min., 5 min |
Field Recalibration |
Allows for recalibration of zero, midscale and span (password protected) |
4-20 mA Output |
- |
12-36 VDC loop,
mA with unlimited turndown (within gauge range) |
- |
Line Powered |
- |
- |
12-36 VDC, 2VA max |
Alarm Switches
(optional) |
- |
- |
(1) or (2) SPDT switches, (max. contact 30VDC, 1 amp, 125VAC 0.5 Amp), Switches adjustable to 100% of range |
Accu-Seal Diaphragm Seal |
System modified to extend the pressure sensor into the process media, thus eliminating any deadleg in the system. Due to the sensor proximity to the threads, some of the stress on the threads during installation can get transferred into the sensor and therefore show up as a zero shift on the display. These shifts are typically small, but should be zeroed out after the unit is installed.
Note: Requires 4-1/2 inch size with 1/2 inch NPT connection. Available with ranges to a maximum pressure 2000 psig
|