AM-540 Detailed Specifications |
FEATURE |
AM-540 |
Best Accuracy |
AC Voltage |
6.000 V, 60.00 V, 600.0 V, 1000 V |
+/- (1.0 % rdg + 3 LSD) |
@ 45 Hz to 400 Hz, 0 V to 600 V |
DC Voltage |
600.0 mV, 6.000 V, 60.00 V |
+/- (0.5% rdg + 2 LSD) |
600.0 V, 1000 V |
@ 6 V to 600 V ranges |
AC Current |
600.0 µA, 6000 µA |
+/- (2.0% rdg + 5 LSD)
@ 45 Hz to 400 Hz |
60.00 mA, 500.0 mA |
10.00 A |
DC Current |
600.0 µA, 6000 µA |
+/- (1.5% rdg + 3 LSD) |
60.00 mA, 500.0 mA |
10.00 A |
Frequency |
60.00 Hz, 600.0 Hz |
+/- (0.1% rdg + 3 LSD) |
6.000 kHz, 60.00 kHz, 600.0 kHz |
6.000 MHz, 60.00 MHz |
Resistance |
600.0 Ω |
+/- (1.0% rdg + 2 LSD)
@ 6 kΩ to 600 kΩ ranges |
6.000 kΩ, 60.00 kΩ, 600.0 kΩ |
6.000 M&Omega 60.00 M&Omega |
Capacitance |
60.00 nF, 600.0 nF |
+/- (3.0% rdg + 5 LSD)
@ 600 nF to 60 µF ranges |
6.000 µF, 60.00 µF, 600.0 µF, 6000 µF |
60.00 mF |
Temperature |
-40 °F to 1832 °F |
+/- (1.0% rdg + 12) @ >104 °F to 752 °F |
-40 °C to 1000 °C |
+/- (1.0% rdg + 8) @ >40 °C to 400 °C |
Number of temperature inputs |
Dual Thermocouple |
|
Duty cycle |
10.00% to 90.00% |
+/- (1.2% rdg + 30 LSD) @ 5 Hz to 2 kHz |
Ambient temperature |
23°C ±5°C (73.4°F ±9°F); Relative temperature: ≤75% |
Accuracy |
±(% of reading + digits) |
Maximum voltage between input terminal and earth ground |
AC 1000Vrms or DC 1000V |
Fuse for mA ?A input |
F1 0.5A H 1000V fast-fuse, (Φ6x32)mm |
Fuse for 10A input |
F2 11A H 1000V fast-fuse, (Φ10x38)mm |
Maximum display |
Digital 5999 counts, updates 3/sec. |
Analog pointer display |
61 segments. Updates 20 times/sec. |
Over-range indication |
OL |
Range |
Automatic and Manual |
Altitude |
Operating ≤ 2000m |
Operating temperature |
0°C~+40°C (32°F~104°F) |
Relative humidity |
0°C~+30°C (32°F~86°F) ≤75%; +30°C~+40°C (86°F~104°F) ≤50% |
Storage temperature |
-10°C~+50°C (14?F~122°F) |
Electromagnetic compatibility |
In an RF ?led of 1V/m = Speci?ed accuracy ? 5% |
Battery |
9V, 6F22, NEDA1604 or equivalent |
Dimensions (L x W x H) |
182 mm x 90 mm x 45 mm (7.2 in x 3.5 in x 1.8 in) |
Weight |
Approx. 354g (0.78 lb) with batteries installed |
DC Voltage Measurement |
Input impedance |
Around 10MΩ ; |
Overload protection |
?1000V |
AC Voltage Measurement |
Overload protection |
1000Vrms |
Input impedance |
Around 10MΩ |
Frequency response |
45Hz- 400Hz (AM-540 / AM-540-EUR), 45Hz - 1kHz (AM-550 / AM-550-EUR) |
AM-540 / AM-540-EUR |
Average sensing, rms indication. |
AM-550 / AM-550-EUR |
True RMS. |
Low Pass Filter |
Overload protection |
1000Vp |
Frequency measurement |
Overload protection |
1000Vp |
Duty Cycle |
Overload protection |
1000Vp |
DC Current Measurement |
Overload protection |
mA /µA range:F1 fuse, 0.5A H 1000V fast-fuse, (Φ 6x32)mm |
10 A range:F2 fuse, 11A H 1000V fast-fuse, (Φ 10x38)mm |
AC Current Measurement |
Overload protection |
µA mA range: F1 0.5A H 1000V fast-fuse, (Φ6x32)mm |
10 A range: F2 11A H 1000V fast-fuse, (Φ 10x38)mm |
Frequency response |
45Hz - 400Hz(AM-540 / AM-540-EUR), 45Hz - 1KHz (AM-550 / AM-550-EUR) |
Resistance Measurement |
Open circuit voltage |
Around 0.5V |
Overload protection |
1000Vp |
Continuity and Diode measurement |
Overload protection |
1000Vp |
Capacitance Measurement |
Overload protection |
1000Vp |
Temperature measurement |
Overload protection |
1000Vp |