General Specifications |
Display |
3-3⁄4 digit LCD (max reading 3999) |
Display Update Rate |
2/sec; |
Overrange Indication |
"OL" indicated |
Low Battery Indication |
Battery symbol appears when battery power is low |
Power Supply |
One 9 V battery (NEDA 1604, IEC 6F22) |
Battery Life |
Alkaline 40 hours, approx. |
Maximum Jaw Opening |
51 mm |
Maximum Conductor Size |
51 mm (2 inches) |
Operating Temperature |
0?C to +50?C, < 75 % R.H. non-condensing |
Storage Temperature |
-20?C to +60?C, < 80 % R.H. non-condensing, batteries removed |
Temperature Coefficient |
0.2 x (Spec. Acc'y), < 18?C or >28?C |
Dimensions (WxHxD) |
240 x 106 x 40 mm |
Weight |
420 g (incl. Battery) |
Electrical Specifications |
AC Current (40-400 Hz) Ranges |
400 A, 1000 A |
AC Current (40-400 Hz) Accuracy |
0 - 40 A ± (1.9 % rdg + 8 dgts) |
AC Current (40-400 Hz) Accuracy |
40 - 400 A ± (1.9 % rdg + 7 dgts) |
AC Current (40-400 Hz) Accuracy |
400 - 1000 A ± (2.9 % rdg + 5 dgts) |
AC Current (40-400 Hz) Crest Factor |
(C.F. 1.4 to 2.0) + (1.0 % rgd) |
AC Current (40-400 Hz) Crest Factor |
(C.F. 2.0 to 2.5) + (2.5 % rgd) |
AC Current (40-400 Hz) Crest Factor |
(C.F. 2.5 to 3.0) + (4.0 % rgd) |
AC Current (40-400 Hz) Position Error |
± (1.0 % rdg) |
AC Current (40-400 Hz) Resolution |
0.1 A in 400 A range |
AC Current (Peak Hold) Ranges |
Low, High |
AC Current (Peak Hold) Accuracy |
± (3.0 % rdg + 10 dgts) |
AC Current (Peak Hold) Resolution |
0.1 A in Low range |
DC Current Ranges |
400 A, 1000 A |
DC Current Accuracy |
0 - 100 A ± (2.9 % rdg + 8 dgts) |
DC Current Accuracy |
100 - 400 A ± (1.9 % rdg + 5 dgts) |
DC Current Accuracy |
400 - 1000 A ± (2.9 % rdg + 5 dgts) |
DC Current Position Error |
± (1.0 % rdg) |
DC Current Resolution |
0.1 A in 400 A range |
Frequency Ranges |
4 kHz, 10 kHz |
Frequency Accuracy |
± (0.5 % rdg + 3 dgts) |
Frequency Resolution |
1 Hz in 4 kHz range |
Min. Input Frequency |
20 Hz |
Sensitivity |
< 1 kHz 6 A rms 1 ? 10 kHz 10 A rms |