Display |
4-4/5 digits 50,000 counts. Selectable stable mode 5-4/5 digits 500,000 counts for DC voltage, & 6 digits 999,999 counts for HZ |
Polarity |
Automatic |
Update Rate |
4-4/5 digits fast mode: 5 per second nominal;
5-4/5 digits stable mode: 1.25 Per second nominal; |
42 Segments Bar Graph |
60 per second max |
Operating Temperature |
0°C to 45°C (32°F to 113°F) |
Relative Humidity |
Maximum relative humidity 80% for temperature up to 31°C decreasing linearly to 50% relative humidity at 45°C |
Pollution Degree |
2 |
Storage Temperature |
-20°C to 60°C (-4°F to 140°F), < 80% R.H.(With battery removed) |
Altitude |
Operating below 2000m |
Temperature Coefficient |
Nominal 0.1 X (specified accuracy)/ °C @ (0°C -18°C or 28°C -- 0°C/32°F- 104°F), or otherwise specified |
Sensing |
AC, AC+DC true RMS |
Safety |
Double insulation per iec61010-1 2nd ed.,En61010-1 2nd ed., Ul61010-1 2nd ed.
& Can/csa c22.2 No. 61010.1-0.92 To category III 1000v AC & DC and category IV 600V AC & DC |
Am-160-a Terminals (to COM)
Measurement Category |
V / A / mAµA |
Category III 1000 VAC & VDC and category IV 600 VAC & VDC. |
Overload Protections |
µA & mA |
0.44A/1000V, IR 10kA or better, F fuse |
A |
11A/1000V, IR 20kA or better, F fuse |
V, mV, e, & others |
1050VRMS, 1450VPEAK |
Transient Protection |
8kV (1.2/50µS SURGE) |
E.M.C. |
Meets en61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000- 4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4- 8, EN61000-4-11) |
In an RF field of 3V/m |
Capacitance function is not specified |
Other Function Ranges |
Total accuracy = specified accuracy + 100 digits.
Performance above 3V/m is not specified |
Power Supply |
Single alkaline 9V battery; neda1604a, jis6am6 or Iec6lf22 |
Power Consumption |
6mA typical |
Low Battery |
Below approx. 7V |
Apo Timing |
Idle for 17 minutes |
Apo Consumption |
5µA typical for am-140-a; 30µA typical for am-160-a |
Dimension |
L317.6 x W177.8 x H76.2 mm (12.5 x 7 x 3in) with clamshell |
Weight |
635g (1.4lb) with clamshell |