Input channels |
4 x AC, ICP power supply on/off
4 x DC for process values
1 x TACHO for speed probe/external trigger |
Input range |
AC +/- 12 V peak-peak
DC +/- 24V |
AD conversion |
24 bit, 64 bit internal signal processing
No AutoGain function! |
Dynamic range S/N |
120 dB |
Frequency ranges (-3 dB) |
Maximum range: 0.35 Hz - 90 kHz (1 Ch, 194 kHz sampling)
Maximum range: 0.35 Hz - 25 kHz (4 Ch, 64 kHz sampling)
Minimum range: 0.35 Hz - 25 Hz (4 Ch, 64 Hz sampling) |
Sampling mode |
Fully simultaneous for 4 channels |
FFT resolution |
Min. 100 lines
Max. 3 276 800 lines |
Unit modes |
Analyzer - analytical measurements
Data collector - route measurements
Balancer - 1 and 2 plane on site balancing
Run up - run up and coast down measurements
Recorder - raw signal recording for later post analysis
Stethoscope - listening of the bearing/machine noise
FASIT - expert system for automatic fault detection
Octave analyzer - hearable sound measurements
Bump test - measurement of natural frequencies
ADS - Animated Deflection Shapes (Operating deflection shapes)
Ultrasound - measurement of ultrasound in 30 - 50 kHz range
Camera
IR Camera
Gallery |
Display |
1125 x 800 pixels |
Built-in camera |
5 MPx, autofocus |
Thermal imaging camera (optionally) |
384 x 288 pixels
-10°C ~ 250°C temp. range
50 mK NETD sensitivity |
Processor |
Intel Atom 1.9 GHz |
Memory, Route |
64 GB, max. 16 GB for one route, number |
of routes is limited by free memory only |
Data processing |
Real time FFT
DEMOD - ENVELOPE analysis
ACMT - low speed bearing analysis
Order analysis
User band pass analysis
RPM measurement
DC measurement
Orbit measurement |
Raw signal recorder |
64 kHz sampling frequency
4 Ch memory consumption 3 GB/hour
4 Ch total recording - 20 hours |
Trigger |
Manual, External, Signal level, Time
Speed change, Time interval |
Interface |
USB 3.0, 2.0 compatible |
Operating temperature range |
10˚C to +50˚C |
Power |
Battery 8 hours of operation, AC 230 V |
Case |
Aluminium heavy duty |
Size & Weight |
29,5 x 23 x 4,9 cm, 2 Kg |