Toll Free: (877) 571-7901
Local: (732) 728-2590
[email protected]
My Account
Sign in to see your member price, rewards, orders, tracking and more.
Why Join? Gain access to exclusive pricing, rewards and more!
Member Pricing & Rewards active
(877) 571-7901
Member Pricing & Rewards are active.
Accurate measurements without the need to precisely position wire or cable in the center of the jaw clamp.SHOP NOW
The SDS3104XHD features an impressive array of measurement and math capabilities, options for a 50 MHz arbitrary waveform generator, as well as serial decoding. SHOP NOW
The Megger IMT100 is the most versatile multi-tester for PV systems, electric vehicles and industrial applications.SHOP NOW
Similar Items
Let us quote you our best price!
Allow us to earn your business and make this purchase easy.
0 reviews | Model: Adash America A4300 RU
Run-up Module - Enables phase related transient data collection such as Bode' Plots, Cross Channel Phase vs Amplitude, Order Analysis, Orbit Plots, Cepstrum, Order Analysis, and other advanced functions.
We accept purchase orders and all major credit cards. We also provide financing via Klarna at checkout for qualifying purchases.
Have a question or need to apply for payment terms?
Contact us.
Have a question? Ask an expert.
Measurement Control When you need to measure Run Up or Coast Down of the machines, then you should use the Runup mode. It enables the same measurements as in Analyzer mode, but controlled by speed, time or uncontrolled. What does it mean "controlled"? In Analyzer mode you can measure the Set and then you have to save measurements manually. The Runup is different. The measurements are saved automatically and additionally the measurements are regularly repeated under the control. The trigger function is used for that control. The menu item Menu/Trigger/Runup mode is used for setting. Usually the speed is used for that control and new measurement is made, when the speed changes from previous measurement of defined value (e.g.10 RPM). Also the time can be used to control that procedure. Then you can take the measurement in defined time interval ( e.g. each 60 sec ). The asap is the next choice. It means no delay between measurements - As Soon As Possible. Be careful for such mode. You can use all memory quickly. The last choice is the Manual mode. You can press the Ok button at any suitable moment to make a new measurement. Available interval is displayed on the status bar before the start of measuring. The instrument enables save up to 1GB of data on each measurement (if enough memory available), but the limit of 1 million values per set cannot be exceeded.
Please select a rating star.
Please complete this field.
Email Adrress is not Valid.
Almost there, please complete all required fields
Out of 5
Average Customer Review
Share your thoughts with other customers