| AEMC 1201.4 Specifications |
| Operating Range |
| Current Range |
50mA to 150AAC/DC in two ranges |
| Frequency Range |
DC to 8kHz |
| Frequency Derating |
| Range Value |
1mV/mA (1V/A), 1mV/A |
| Frequency Range |
DC to 2kHz, DC to 8kHz |
| Common Mode Voltage |
600VAC max |
| Load Impedance |
1MW |
| Load Impedance |
| Range Value |
1mV/mA (1V/A), 1mV/A |
| Load Impedance |
100 kW, 10 kW |
| Reference Conditions |
23°C ±5°K, 20 to 75% RH, 48 to 65Hz, external magnetic field <40A/m, no external current carrying conductor, test sample centered. Load impedance 1MW |
| Working Voltage |
600VAC max |
| Noise |
| Current Range |
50mA to 2ADC; 50mA to 1.5AAC, 500mA to 150A |
| Range Value |
DC to 1Hz, 1 Hz to 10kHz, 10 to 100kHz, DC to 1Hz, 1 Hz to 10kHz, 10 to 100kHz |
| Noise |
3mV, 10mV, 18mV, 3µV, 10µV, 18µV |
| Output Signal |
| Range Value |
50mA to 2ADC; 50mA to 1.5AAC, 500mA to 150A |
| Output Signal |
1V at 1AAC/DC, 100mV at 100AAC/DC |
| Accuracy |
| Range |
1mV/mA (1V/A), 1mV/A |
| Current Range |
50mA to 2A DC; 50mA to 1.5A AC, 500mA to 150A |
| Range Value |
500mA to 100A AC/DC, 100 to 150A DC, 100 to 120A AC |
| Accuracy % of Reading |
2% of Reading ± 20mA, 1.5% of Reading ± 30mA, ± 3% of Reading : 3% of Reading |
| Phase |
| Range |
1mV/mA (1V/A), 1mV/A |
| Range Value |
45 to 65Hz |
| Phase Shift |
3°, 1° |
| Mechanical Specifications |
| Altitude |
Operating: 0 to 2000m; Non-operating: 0 to 12km |
| Typical Consumption |
6mA |
| Battery Life |
68 hours typical |
| Colors |
Dark gray |
| Dimensions |
9.09 x 1.42 x 2.64 (231 x 36 x 67mm) |
| Drop Test |
1.0m on 38mm of oak on concrete; (IEC 68-2-32) |
| Low Battery |
Green LED when ³ 6.5 V |
| Material |
Handle: Lexan 920A, UL 94 V2 |
| Maximum Cable Diameter |
0.46" (111.8mm) |
| Mechanical Shock |
100g per IEC 68-2-27 |
| Operating Temperature |
32° to 122° F (0° to 50° C) |
| Operating Relative Humidity |
10° to 30° C: 85 ± 5% RH (without condensation); 40° to 50° C: 45 ± 5% RH (without condensation) |
| Output |
Double insulated 5 ft (1.5m) lead with safety banana plugs |
| Power Supply |
9V Alkaline (NEDA 1604A, IEC 6LR61) |
| Protection Index (IP) |
IP20 per IEC 529 |
| Impact Test |
IK04 0.5 J EN50102 |
| Storage Temperature |
-22° to 176° F (-30° to 80° C) |
| Vibration |
Test per IEC 68-2-6 |
| Weight |
11.6 oz (330g) with battery |
| Zero Adjustment |
20 turn potentiometer |
| External Influences |
| Influence of Temperature |
<0.2% per ° C |
| Safety Reference Specifications |
| Safety Ratings |
EN 61010-2-32 |
| Agency Approvals |
CE Mark |