| AEMC 2124.57 Specifications |
| INTERFACE |
| Screen Specifications |
Color 5 x 7" LCD (115 x 86mm) 320 x 240 CCFL backlighting |
| Display Mode |
Vectors with interpolation |
| No of Curves on Screen |
Four curves and four references Split-screen and full-screen modes (tracing zone 110 x 74) |
| Front Panel Control |
32 direct shortcuts |
| Screen Control |
Touch screen - "Windows-like" menus and graphic commands |
| Languages |
Five complete languages, menus, and on-line help (English, French, German, Spanish, Italian) |
| VERTICAL |
| Verticle Sensitivity |
16 ranges from 2.5mV 200V/div and up to 15 /div in verticle zoon mode (12-bit converter) Accuracy 1% |
| Bandwidth |
Bandwidth 100Mhz |
| Channels |
Two isolated channels |
| Input Impedance |
1M ± 0.5% |
| Maximum Permanent Input Voltage |
600V Cat. III Derating -20dB/decade at 100kHz |
| Vertical Sensibility |
16 ranges from 2.5mV to 200V/div |
| Accuracy |
±1.5% |
| Vertical Zoom |
x5 maximum |
| Probe Factors |
1 / 10 / 100 / 1 000 or scaling to any value Definition of the measurement unit |
| HORIZONTAL |
| Time Base Speed |
35 ranges from 1ns/div to 200s/div |
| Accuracy |
±1.5% |
| Horizontal Zoom |
x10 maximum |
| TRIGGERING |
| Mode |
Auto, trigger, single, Auto 50% |
| Source |
CH1, CH2, CH3, CH4 |
| Type |
Front, pulse or delay (20ns/340s), count (2/16384), or TV (525 or 625 lines) |
| Coupling |
AC, DC, HFR, LFR, noise reduction Hold-off adjustable from 40ns to 1s |
| Sensitivity |
0.6 div to 1KHz / 1.5 div to 150MHz |
| DIGITAL MEMORY |
| Maximum Sampling Speed |
50GS/s in ETS 1GS/s in one-shot mode on each channel |
| Vertical Resolution |
12 bits |
| Memory Capacity per Channel |
|
| User Memory |
1 MB |
| Other Modes |
Envelope mode (Factors from 2 to 64)
XY Mode Between two from the four curves math functions and cursors |
| OTHER FUNCTIONS |
| Autoset |
Complete auto set at less than 3s, with recognition of channels Frequency : > 30Hz |
| FFT |
Analyzer and Math Functions FT, + , - , x , / - Editor of mathematical functions |
| Cursors |
Two or three cursors: V and T simultaneous or Phase Resolution 12 bits, display four digits |
| Automatic Measurements |
18 level or time measurements, phase measurements Resolution: 12 bits, display four digits |
| MULTIMETER |
| AC, DC, AC + DC voltage |
From 400.0mV to 600.0VRMS or 800.0VDC - Accuracy VDC 0.5 % R+ 5D bandwidth 50kHz |
| Resistance |
80.00 to 32.00M - Precision 0.5 % R+ 5D - Rapid 10-ms continuity test |
| Other Measurements Capacities |
5.000nF to 50.00mF/Frequency 200.0MHz - Diode test 3.3V |
| RECORDER (option) |
| Acquisition Rate Sampling |
The interval from 500μs to 10mn |
| Duration of Recording |
From 25s to 34 days 16h 20mn |
| Acquisition Mode |
Conditional on thresholds or windows Normal or "50-faults" acquisition |
| Operation |
Timestamped graphic recording, conversion, and units of physical quantities, measurement using cursors and search for events, standard file format usable in spreadsheets (.TXT) |
| HARMONIC ANALYZER (option) |
| Analysis |
Span Even or odd orders up to 31, or first 16 orders |
| Operation |
Permanent display: total RMS value and harmonic factor
Order selected: % F, phase, freq, VRMS |
| GENERAL SPECIFICATIONS |
| Configurations |
Memories Unlimited - CF file size approx. 1kB |
| Ethernet Network Printing Standard |
11 black and white or color drivers - IBM Proprinter, Epson ESC/P, Canon HP PCL, Seiko DPU411 |
| RS-232 or Centronics Options |
Postscript Image files - BM 10kB, GI approx. 5kB (storage in memory transfer by RS-232 or Ethernet) |
| Communication |
Local via Ethernet 10 MB or RS 232 (option) - Remote via 10 MB Ethernet and web server
x-Metr application software for PC (option) |
| Power Source |
9.6V/3.8 A/h battery pack - Approx. 4h between charges - Adjustable power-saving switching |
| Multi-voltage |
98-254V / 47-63Hz - Fast charge in 2 hours (oscilloscope off) |
| Dimensions |
10.25 x 7.25 x 2" (261 x 185 x 53mm) |
| Weight |
4.2 lbs (1.9kg with batteries) |