| AEMC 2138.01 Specifications |
| INSULATION |
| Rated voltage |
Utest: 50 /100 / 250 / 500 / 1000 V DC |
| Range / Resolution / Accuracy |
0.01 MΩ to 2 GΩ / 1 kΩto 1 MΩ / ±(5 % of measurement + 3 cts) |
| EARTH |
| 3P EARTH |
| Range / Resolution / Accuracy |
0.50 to 4 kΩ / 0.01 Ω to 1 Ω / ±(2 % of measurement + 2 cts) |
| Others |
Auxiliary stake resistance measurement (up, to 40 kΩ) |
| EARTH WITH POWER ON |
| Installation voltage / Frequency |
90 to 550 V / 15.3 to 17.5 Hz - 45 to 65 Hz |
| 1P EARTH |
| High-current mode with tripping (TRIP) |
Test current: 5 A |
| Range / Resolution / Accuracy |
0.10 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(5 % of measurement + 2 cts) |
| Mode without tripping (NO TRIP) |
Test current: 6 mA - 9 mA - 12 mA (by default) |
| Range / Resolution / Accuracy |
0.20 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(5 % of measurement + 3 cts) |
| 1P SELECTIVE EARTH |
| Range / Resolution / Accuracy |
0.20 Ω to 3,999 Ω / 0.01 Ω to 1 Ω / ±(10 % of measurement + 10 cts) |
| RCDs |
| Installation voltage / Frequency |
90 V to 550 V / 15.3 Hz to 17.5 Hz / 45 Hz to 65 Hz |
| IΔn |
10/30/100/300/500/650/1,000 mA or variable - Test in step and pulse modes |
| No-trip test |
at ½IΔn - Duration: 1,000 ms or 2,000 ms |
| Measurement of tripping time |
at ½IΔn / 2 IΔn (selective) / 5 IΔn |
| Step mode |
0.3 IΔn to 1.06 IΔn in steps of 3.3 % IΔn |
| CONTINUITY |
| Test voltage/ I rated |
9.5 VDC / I > 200 mA up to 39.99 Ω and 12 mA up to 399.9 kΩ with buzzer |
| Range / Resolution / Accuracy |
0 Ω to 399.9 kΩ / 0.01 Ω to 100 Ω / ±(1.5 % of measurement + 2 cts) |
| LOOP IMPEDANCE (Zi and Zs) |
| High-current mode with tripping (TRIP) |
Test current: 5 A |
| Range / Resolution / Accuracy |
0.1 Ω to 4,000 Ω/ 0.01 Ω to 1 Ω / ± (10 % of measurement + 5 cts) |
| NO TRIP mode (Zs only) |
Test current: 6 mA - 9 mA - 12 mA (by default) |
| Range / Resolution / Accuracy |
0.2 Ω to 4,000 Ω / 0.01 Ω to 1 Ω / ± (10 % of measurement + 5 cts) |
| Calculation of short-circuit current |
0.1 A to 40 kA |
| Other |
Measurement of the resistive and inductive components of the impedances Zs and Zi |
| CURRENT |
5 mA to 19.99 A (MN77 clamp) / 5 mA to 19.99 A (C177 clamp) / 20 mA to 200 A (C177A clamp)
Current measurement from 1 mA available with MN77 & C177 by connecting voltage on the product |
| VOLTAGE |
0 to 550 V AC/DC |
| FREQUENCY |
DC / 15.3 to 500 Hz |
| ACTIVE POWER |
0 to 110 kW single-phase - 0 to 330 kW three-phase
Simultaneous display of voltage and current waveforms. |
| HARMONICS |
Voltage and current harmonics / Orders 0 to 50 / THD |
| PHASE ROTATION |
20 to 550 VAC |
| GENERAL SPECIFICATIONS |
| Display |
Large 5.7” backlit graphic screen, 320 x 240 counts |
| Memory / Communication |
via USB for data transfer and report creation |
| Power supply |
Rechargeable battery |
| Dimensions / weight |
280 x 190 x 128 mm / 2.4 kg |
| Protection rating |
IP 53 |
| Electrical safety |
IEC 61010-1 - 600 V CAT III - IEC 61557 |