AEMC 2111.27 Specifications |
CURRENT TRUE RMS |
INPUT RANGE |
1 to 500 Arms |
TYPICAL ACCURACY (and Phase Shift) |
with 500 A Current Probe MD313: 25 A: 5%R (4°), 100 A: 2%R (2°), 500 A: 2%R (1.5°) |
TYPICAL ACCURACY (and Phase Shift) |
with 1000 A Current Probe SD613: 50 A: ±0.9%R (1.5°), 200 A: ±0.5%R (0.5°), 1000 A: ±0.5%R (0.5°) |
RESOLUTION |
1 to 9.99 A: 10 mA, 10.0 to 99.9 A: 100 mA, 100 A to 500 A: 1 A |
VOLTAGE TRUE RMS |
INPUT RANGE |
0 to 600 Vrms |
ACCURACY |
1 to 99.9 V: 0.5% ±0.6 V, 100 to 600 V: 0.3% ±2 V |
RESOLUTION |
0 to 99.9 V: 0.1 V, 100 to 600 V: 1 V |
VOLTAGE DC |
VOLTAGE DC |
INPUT RANGE |
0 to 600 V DC |
FREQUENCY INPUT RANGE (from voltage input) |
30 to 100 Hz, 101 to 999 Hz |
ACCURACY |
30 to 100 Hz: 0.03%R ± 0.1 Hz, 101 to 999 Hz: 0.5%R ± 1 Hz |
POWER FACTOR |
POWER FACTOR |
RANGE |
-0.00 (Lag) to +0.00 (Lead) ACCURACY: Sum of the V, A accuracy plus the probe phase shift |
ACTIVE POWER RANGE |
0 to 300 kW (600 kW with SD613 probe) ACCURACY: Sum of the V and A accuracy |
REACTIVE POWER RANGE |
0 to 300 kVar (600 kVar with SD613 probe) ACCURACY: Sum of the V and A accuracy @ Sin F = 1 |
APPARENT POWER RANGE |
0 to 300 kVA (600 kVA with SD613 probe) ACCURACY: Sum of the V and A accuracy |
GENERAL Specifications |
DISPLAY |
40 x 50 mm multidisplay LCD |
POWER |
Four 1.5 V AA alkaline batteries |
Low Battery Indicator |
BAT on display |
BATTERY LIFE |
50 hours approx., continuous use |
DIMENSIONS |
3.2 x 6.9 x 1.3" (80 x 175 x 32 mm) With yellow holster: 3.5 x 7.7 x 2.1" (90 x 195 x 54 mm) |
WEIGHT |
With batteries: 0.9375 lbs
In yellow holster: 1.1 lbs |
CURRENT PROBE |
Accommodates two 500 MCM or one 750 MCM |
Safety Specification |
PROTECTION LEVEL |
IEC 348 Class II |
PROTECTION INDEX |
IP40 per IEC 529 |
MAX. OVERLOAD |
VOLTAGE: 825 Vrms, 1170 V peak |