Ground Resistance Tester
The Ground Resistance Tester Model 6471 is a portable measurement instrument designed to measure Ground Resistance with 2 clamps (no auxiliary rods), Bond/Connection Resistance (2-Pole and 4-Pole Kelvin sensing), Ground Resistance (3-Pole or 4-Pole), Ground Coupling Resistance, and Selective Ground Resistance, Soil Resistivity (Wenner or Schlumberger method). The Model 6471 measures from 0.01 to 99.99kO and is auto-ranging, automatically seeking out the optimum measurement range, test frequency, and test current.
Easy-to-use - Simply connect the leads, select the test mode, press Start and read the results. Up to 512 test results can be stored in internal memory for later recall to the display or downloaded to a PC via DataView® software.
The Model 6471 is Cat IV rated to 50V and is over voltage protected to more than 250VAC against accidental connection to live circuits. The voltage is also displayed on the screen. In the event of a system fault, the Model 6471 can withstand 250VAC.
Additional features of the Model 6471 include a heavy-duty field case sealed against dust and water when closed (the test button is also sealed against the elements); manual and automatic test frequency selection from 41 to 513Hz; user-selectable 3-Pole Fall of Potential or 4-Pole Soil Resistivity test methods and user-selectable 2-Pole or 4-Pole Bond Resistance test method. The Ground Resistance Tester Model 6471 is rugged, easy-to-use, and ideal for maintenance crews performing numerous tests. It exceeds mechanical and safety specifications for shock, vibration, and drop tests per IEC standards. The adjustable test frequency provides for rejection of high levels of interference, allowing it to be used under difficult conditions such as high stray currents that affect accuracy.
Features
- Optically isolated USB communication
- Remote set up and operation of all measurements using DataView® software
- Rechargeable NiMH batteries from wall charger or vehicle power
- Rugged dustproof and rainproof field case - IP54 rated in closed position
- Grounding standards IEC 61557 parts 4 and 5 compliant
- Includes DataView® software for data storage, real-time display, analysis, report generation and system configuration
Applications
- 3-Point measurements of resistance to ground of ground rods and grids. 3-Point measurements are generally used when the electrode or grid can be easily disconnected.
- 4-Point tests or soil resistivity measurements. Locating areas of the lowest soil resistivity is essential for achieving an economical grounding installation.
- Touch and step potential testing measurements. These tests are recommended when the ground cannot be disconnected, where ground faults are highly likely to occur, or when the “footprint” of grounded equipment (the outline of the part of equipment in contact with the earth) is comparable to the size of the ground to be tested.
- 2- or 4-Wire tests for continuity tests on bonding or on grounding systems. The test is a DC resistive test using 250mA or more and is used to check the bonding of all connection points on the ground system.
- Earth coupling measurement and display. Used to estimate the influence of two earth resistance systems that are not connected to each other.